00198156-01_AI_Long-Board-Option_EN.pdf - 第17页
Installing 2.1.2 Installation Installing the LBO E Kit Assembly Instructions E by SIPLACE 17 ► Install the "E-series conveyor stopper unit" [03106565-xx] (1) with " M3x6 cap screws" (2) ► Connect the …

Installing
Installing the LBO E Kit 2.1.2 Installation
16 Assembly Instructions E by SIPLACE
2.1.2.3
2.1.2.3 Stopper (All Versions)
Stopper (All Versions)
Right side
Left side
► Undo the countersunk M3x6 screws and M4x8 screws (1) to access the internal parts of the stopper
rail.
► Remove the 700 mm LBO sticker (1) from the cover
► Remove the cover (2).

Installing
2.1.2 Installation Installing the LBO E Kit
Assembly Instructions E by SIPLACE 17
► Install the "E-series conveyor stopper unit" [03106565-xx] (1) with " M3x6 cap screws" (2)
► Connect the cable.
► Paste the "Hot temp warning label" [03107383-xx] (3) over the gap around the external area of the
stopper.
► Shift the sensor toward the output area.

Installing
Installing the LBO E Kit 2.1.2 Installation
18 Assembly Instructions E by SIPLACE
► Install the "E-series reverse stopper unit" [03108720-xx] (1) using the "M3x6 cap screws"
[03042540-xx].
► Install the "E-series stopper bracket" [03107923-xx] (2) using the "M3x6 countersunk screws"
[03082814-xx].
► Install the "Sonar Sensor UB100-F77" [03089004-xx] (3) using the "M3x16 cap screw" [03042545-
xx].
► Route all option cables by following the original cable routing.
► Refit the stopper rail cover.