00198156-01_AI_Long-Board-Option_EN.pdf - 第22页
Installing Installing the LBO E Kit 2.1.2 Installation 22 Assembly Instructions E by SIPLACE Standard flow (Right Fix) → (Single line connections)
Installing
2.1.2 Installation Installing the LBO E Kit
Assembly Instructions E by SIPLACE 21
2.1.2.5
2.1.2.5 Cable Harness (All Versions)
Cable Harness (All Versions)
► Connect the designated cable harness as per below conveyor option configurations.
Connections points are in the Standard flow and Reverse flow schematics.
LBO E 1200 [03110518-xx] and LBO E 1030 [03108019-xx]
▪ Standard flow (Right Fix)
– Cable, stopper, LBO, trk1 [03101844-xx]
– Cable, PCB sensor, LBO, trk1 [03101834-xx]
– Cable, stopper, reverse, trk1 reverse [03108854-xx]
– Cable, stopper ext, LBO Reverse trk 1 [03114850-xx]
▪ Reverse flow (Left Fix)
– Cable, stopper, LBO, trk1 [03101844-xx]
– Cable, stopper ext, LBO, trk 1 [03114849-xx]
– Cable, PCB sensor, LBO, trk1 [03101834-xx]
– Cable, stopper, reverse, trk1 reverse [03108854-xx]

Installing
Installing the LBO E Kit 2.1.2 Installation
22 Assembly Instructions E by SIPLACE
Standard flow (Right Fix) → (Single line connections)

Installing
2.1.2 Installation Installing the LBO E Kit
Assembly Instructions E by SIPLACE 23
Reverse flow (Left Fix) → (Single line connections)