5 Restrictions
In the following, existing restrictions in SIPLACE Pro are described.
Miscellaneous
10-fold and 15-fold stick magazines cannot be combined on the same linear feeder.
SIPLACE Pro object names (e.g., recipe) must not exceed 125 ASCII characters (including
folder names). If the station software is 504 or older, these names are shortened to 20 ASCII
characters.
If various users optimize the same job at the same time, the job which was most recently
completed successfully will overwrite all corresponding recipes
The operator must manually place manual tray carriers (Carrier 30, Carrier 51, Carrier X,
Carrier SX, Arbitrary Carrier), glue feeders and dip modules in the initial setup.
If you work with reduced acceleration for a component shape, this is seen as a "special case"
and the accuracy of 5% for the simulated Optimizer production time will not be achieved.
The Optimizer does not check if the tray size is bigger than the carrier.
The WPC can take up to 10 different component types per level. This restriction does not apply
for machines from station software version 70x.
Station-wise Download
It is not possible to switch over from dual lane conveyor in asynchronous transport mode to
dual lane conveyor in synchronous transport mode (and vice versa) in combination with station-
wise download.
When the line control server is rebooted, station-wise downloading will be canceled. After
rebooting, you will need to perform a complete line download to restart production.
Station-wise downloading supports setup changes in asynchronous dual operation only when
you have the same definition for both lanes.
Station-wise downloading supports synchronous dual operation as of station software version
704.
ASCII Centroid Import
If component shapes are selected in the ASCII Centroid Import Wizard, all the existing links
between components and component shapes will be overwritten with the imported information.
WPC5 / WPC6
Components up to a height of 30mm can be placed with a force of 70N with the WPC5 as of
serial number 1485 and the WPC6 as of serial number C1486 only.
Components up to a height of 40mm can be placed with the WPC5 as of serial number B3000
and the WPC6 as of serial number C3000.
Due to the refill module, components > 25mm cannot be positioned on the levels 1 3 and
2728 on the WPC6. The levels 4 28 will be set up automatically by the SIPLACE Pro
Optimizer. The levels 1 3 have to be blocked manually by the operator.
If a pin picker is installed on the X4i S placement machine, the maximum board length is
410mm.
SIPLACE Pro 14.0 (R16-2) / Version Description 12/2016 Edition
20
Binning can be disabled in SIPLACE Vision
If binning is disabled in SIPLACE Vision, the measuring in the simulation result of the
optimization will probably take a little longer.
External virtual ink spot handling
Only possible for stations from station software version 707.0 on.
Physical and virtual ink spot must not be mixed.
The board must not contain any active ink spots.
Restrictions in the Production Schedule
PCB barcode mode is not supported.
Spring placement process
The board top edge position has to be constant from board to board to allow absolute placement.
Variable board warpages cannot be compensated.
Measuring and changing the component height measured by the component sensor at the
station
Only for nozzle and component combinations in which the component height is supposed to be
measured with the component sensor.
The component sensor will not perform any measurement if the component height
measurement is omitted due to SIPLACE Pro rules.
Conveyor Carrier X
No travel range check.
No pickup simulation.
The Conveyor Carrier X uses one track on an X-table virtually. If the real table should be
completely occupied, the operator might have to remove a feeder from the table to create place
for the virtual feeder.
No I-Placement mode.
The SIPLACE Pro Optimizer does not consider the time it takes to fill up a tray with
components and change it.
Heavy Board Mode per board side
No barcode mode possible.
Board Identification
The Barcode located under the board property cannot be combined with the board barcode
mode.
Shuttle Extension for TX-series
Barcode mode and station-wise download are not supported.
SIPLACE Pro 14.0 (R16-2) / Version Description 12/2016 Edition
21
6 Troubleshooting
Error Reporting Tool
The Error Reporting Tool allows you to transfer detailed information about any errors occurring in
SIPLACE Pro to the service team. For more information about this function, refer to section 7.1
ASM Error Reporter Service, the Online Help or the Support Media.
Error Reports with the ASM Error Reporter Service
The ASM Error Reporter Service can be started as follows:
Via StartProgramsASM NetEnterprise ServiceASM Error Reporter Service
Via HelpError Reporting in the menu of the GUIs.
Follow the instructions on the screen.
6.1 Problems and Solutions
This section describes known circumstances and general problems. If applicable, troubleshooting
is provided to help you working with SIPLACE Pro.
Solving Problems in Workgroup Mode
If you operate SIPLACE Pro in workgroup mode and if e. g. during the startup of the SIPLACE Pro
LineControl GUI application a message is displayed stating that:
It was not possible to establish a connection to the SIPLACE Pro
Interface. The cause for the error was: Unknown error (0x80004005).
Check, if the following password requirements are met:
The local user data must also be set up on the workgroup server.
The local user must have the same password as on the workgroup server.
Printing SIPLACE Pro Reports
The generated reports can be sorted by various criteria (such as placement list etc.). Within the
printing preview the sort criteria can be modified as well.
Check your specific printer properties (e.g. borderless printout) if you have printing problems
when printing reports.
Backup of System Feeder Inventory
When upgrading SIPLACE Pro (starting with SIPLACE Pro 3.0) an updated system feeder
inventory is imported (SystemFeederInventory.xml) in order to consider all new feeder types. The
feeder inventory that is already existing in SIPLACE is renamed (Backup of System Feeder
Inventory_X). All existing jobs are not changed.
All new jobs contain the updated (newly imported) feeder inventory.