00196497-07_SM_SXDX12_en.pdf - 第95页

Service Work Conveyor 3.4.10 Replacing the Vision Hotlink Adapter [03050555 -xx] Gantries Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 95 Installation ► Follow the removal in structions in reverse order for installati o n…

100%1 / 334
Service Work Conveyor
Gantries 3.4.9 Replacing the Vision Board Spread Spectrum HCU [03067289-xx]
94 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
3.4.9
3.4.9 Replacing the Vision Board Spread Spectrum HCU [03067289-xx]
Replacing the Vision Board Spread Spectrum HCU [03067289-xx]
Parts, Equipment and Tools
Vision Board Spread Spectrum HCU assembly [03067289-xx]
Overview
Removal
Boards on the Gantry
1. Vision board spread spectrum
2. Head adapter (here the version for the TwinHead with
two HCUs)
3. HCU
4. Head interface
5. Sensor module X
Switch off the machine, disconnect it from the power
supply and secure it to prevent unauthorized reacti-
vation. Observe the instructions in section "1.2 Pre-
paratory Work..." [ ➙ 13].
If there is a cover above the boards, dismantle it.
Open the cable clamps (2) on the two PCB camera
cables (4) and disconnect the cables. You may want
to mark their positions, to make clear assignment
easier later on.
Disconnect the flat ribbon cable (3).
Remove the cable tie. (5).
Undo the five screws (1) fastening the Vision board
spread spectrum and remove the board.
Service Work Conveyor
3.4.10 Replacing the Vision Hotlink Adapter [03050555-xx] Gantries
Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02 95
Installation
Follow the removal instructions in reverse order for installation. Also observe the following instruc-
tions:
See also
5.2.2 Vision board spread spectrum HCU1 [03067289-xx] [ ➙ 314]
3.4.10
3.4.10 Replacing the Vision Hotlink Adapter [03050555-xx]
Replacing the Vision Hotlink Adapter [03050555-xx]
Parts, equipment and tools
Vision hotlink adapter VHA [03050555-xx]
Overview
CAUTION
Installation instructions
If there is no clamp for the PCB camera cable on the new board, take this off the old board
and fit it on the new one.
Then perform a firmware update.
1. Sector 1
2. Vision hotlink adapter
3. Sector 3
The Vision hotlink adapter for gantry 1 is located in
sector 1.
The Vision hotlink adapter for gantry 2 (SX 2 only) is lo-
cated in sector 3.
Service Work Conveyor
Gantries 3.4.10 Replacing the Vision Hotlink Adapter [03050555-xx]
96 Service Manual SIPLACE SX1/SX2/DX1/DX2 FS02
Removal
Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 13].
Unplug the electrical connections to the trailing cable interface and the Vision hotlink adapter. Mark
their positions, to make clear assignment easier later on.
Loosen the two screws fastening the mount. You can then push the mount backwards and lift it off
the fastening screws.
Loosen the 4 screws fastening the Vision hotlink adapter and remove it from the mount.
Installation
Follow the removal instructions in reverse order for installation.
See also
5.2.6 Vision hotlink adapter [03050555-xx] [ ➙ 320]
1. Screws fastening the mount
2. Mount
3. Trailing interface