00195427-02_AI_HeadReconfigKitsD1D2_DE+EN.pdf - 第80页

If only one head is assembled, the T -piec es must be sealed with blind plugs. 2 Under no circumst ances, must blind plugs and others be able to make contact with the ribb on cable - also not in the end position. 2 Assem…

100%1 / 94
Assembly instructions Head Reconfiguration SIPLACE D1 / D2
Edition 03/2007
77
: Fix the P&P head with 4 screws DIN912 M4x16 - 8.8 (03052012-).
Tighten the screws crosswise with a torque of 270 Ncm.
2
Fig. 2.8.2 Fix C&P: Torque screw driver with pivot extension insert bit
: Connect the 3 hoses.
2
Fig. 2.8.3 Connect silicon hose size 12
If only one head is assembled, the T-pieces must be sealed with blind plugs. 2
Under no circumstances, must blind plugs and others be able to make contact with the ribbon
cable - also not in the end position. 2
Assembly instructions Head Reconfiguration SIPLACE D1 / D2
Edition 03/2007
78
2
Fig. 2.8.4 Connect silicon hose size 8 and 6
2
2
2
2
Assembly instructions Head Reconfiguration SIPLACE D1 / D2
Edition 03/2007
79
2
Fig. 2.8.5 Single Head: T pieces with blind plugs
2
: If necessary shorten the two hoses to the head to the extent that the plugs have no contact
also in the outermost gantry position. The hoses must not kink however!
2
2
2
2
2
2
2
2
2
2
2