Formflex Manual.pdf - 第12页

TECHNI CAL R EFEREN CE PNEUM ATIC SC HEMAT IC Chapter Issue 4 Jun 04 FormFlex Tooling M anual 1.5 PNEUMA TIC SCHEMA TIC T ooling Modules Sequencing Manifold Exhaust V enturi V acuum Unit Non Return V alve Main Air Supply…

100%1 / 43
1.4 FormFlex Tooling Manual Chapter Issue 4 Jun 04
TECHNICAL REFERENCE
ELECTRICAL SCHEMATIC
ELECTRICAL SCHEMATIC
Solenoid Valve 1
(Tooling Modules)
Solenoid Valve 2
(Tooling Modules)
Solenoid Valve 3
(Tooling Modules)
Solenoid Valve 4
(Fluid Cut-Off Valve Override)
Solenoid Valve 5
(Venturi Vacuum Unit)
M34
Control Pod
M34PL04
E E E
Operator Switch
Operator Switch LED
Reset Switch
Exercise Switch
FS01
M34SK01
M34SK03
24V US
OV
M24 dc Power Supply
(600 series)
M37 Power Supply
(700 series)
M24PL05 (600)
M37PL10 (700)
TECHNICAL REFERENCE
PNEUMATIC SCHEMATIC
Chapter Issue 4 Jun 04 FormFlex Tooling Manual 1.5
PNEUMATIC SCHEMATIC
Tooling Modules
Sequencing Manifold
Exhaust
Venturi Vacuum
Unit
Non Return
Valve
Main Air Supply
AB
AB
AB
AB
AB
1
2
3
4
5
Solenoid Valve Manifold
Override Manifold
1.6 FormFlex Tooling Manual Chapter Issue 4 Jun 04
TECHNICAL REFERENCE
ADJUSTMENTS AND SETTINGS
ADJUSTMENTS AND SETTINGS
FormFlex Pin Pressure
WARNING
BOARD CLAMPS. EXTREME CARE MUST BE EXERCISED WHEN WORKING IN
THE TOOLING AREA OF THE MACHINE TO AVOID INJURY. THE FOILS ON THE
FRONT AND REAR BOARD CLAMPS ARE VERY SHARP.
WARNING
COMPRESSED AIR. COMPRESSED AIR SHOULD NEVER IMPINGE UPON THE
BODY. PORTS, PIPES, ETC MUST NEVER BE BLOCKED BY HAND. BEFORE
CONNECTING ANY PNEUMATIC EQUIPMENT TO A COMPRESSED AIR SUPPLY,
ALL MOUNTINGS, FITTINGS, PIPEWORK AND ELECTRICAL CONNECTIONS
SHOULD BE REMOVED FOR SAFETY. NO PIPEWORK ALTERATIONS OR
REMOVAL OF FITTINGS SHOULD BE ATTEMPTED WITH AIR SUPPLIES
CONNECTED.
1. Gain access to the manual tooling plate.
2. Connect the module under test to one of the outlets of the sequencing
manifold.
3. Fully tighten the two registration grub screws fitted to the base of the module
(front tooling module only).
4. Place the setting weight over the tooling module, covering 6 FormFlex pins.
5. Press the amber operator button on the machine front cover.
NOTE
The amber operator button flashes during setup and changes to continuous
amber when complete.