WPC an:on SIPLACE SX1:SX2 Montageanleitung : Assembly Instructions.pdf - 第49页

1 Introduction Mo nt ag ea nl ei tu ng / A ss em bl y In st ru ct io ns W PC a n/ on S IP LA CE S X1 /S X2 - 0 3/ 20 25 49 Machine switched off at the main switch, but still connected DANGER Risk of death by voltages! De…

100%1 / 82
1 Introduction
48 Montageanleitung / Assembly Instructions WPC an/on SIPLACE SX1/SX2 - 03/2025
1.1.4 Safety instructions for the power supply (with SMPS)
NOTICE
Validity
This section applies to the following machine types with SMPS (Switched Mode Power Supply):
SIPLACE SX1/SX2 edition V3 from serial no. Rxxxx
SIPLACE SX1/SX2 edition V2 from serial no. Nxxxx
Residual voltages and discharge times in the machine
If the emergency stop button is pressed or the machine is switched off, the 300V~ link voltage for the
gantry axes and the 160V~ link voltage for the star axes are reduced to harmless residual voltages in
a very short time.
CAUTION
Residual voltages
After switching off the machine, wait at least 10 seconds before you switch it back on again, so
that stored residual voltages can dissipate.
Please note that longer waiting periods apply when working on the power supply.
DANGER
Dangerous voltages!
The machine is supplied with 3 x 380 V~ to 3 x 415 V ± 10 %, 50/60 Hz or optional with 3 x 200 V~ to
3 x 220 V~ ± 10 %; 50/60 Hz mains voltage and contains energy-storing components. This means
that some parts of the system carry potentially lethal voltages - even when it is switched off at the
main power switch and the power plug is unplugged.
Death, serious bodily injury or considerable damage may result if these machines are handled incor-
rectly.
Always follow the applicable accident prevention and DIN regulations (particularly EN60204,
part 1 or IEC 60204, part 1) and the applicable regulations in your own country.
The covers of the power supply unit may only be opened by appropriately qualified and trained
personnel.
Please observe the safety instructions in the user manual for all work!
Before you start working on the power supply, check it for absence of voltage and observe the
indicated waiting times!
CAUTION
Loss of data!
To avoid losing data, assess that the following criteria have been met before switching off your
machine (apart from in emergencies):
The machine has finished transmitting machine, setup and panel data.
The machine has finished processing the PCB.
The machine has completed the run-up phase.
1 Introduction
Montageanleitung / Assembly Instructions WPC an/on SIPLACE SX1/SX2 - 03/2025 49
Machine switched off at the main switch, but still connected
DANGER
Risk of death by voltages!
Death, serious injury or considerable damage may result if these machines are handled incorrectly.
The following components still carry potentially lethal voltages on the power supply even if the main
power switch is switched off:
Main power supply cable connection terminals
L1, L2, and L3 of the main switch S1
Service socket X98 (if present)
The contactor safety breaker (CBS) still carries voltage for five minutes after switching off
at the main switch.
Make sure that you wait another five minutes before performing tasks on the CSB.
The color of all individual wires which still carry potentially lethal voltages even if the main power
switch is switched off is orange.
Fig.1: Power supply unit (SIPLACESX1/SX2 edition V3,
SMPS)
1. Main switch (S1)
2. Measuring points
3. Main power supply cable connection termi-
nals (X94) for the power supply cable
Fig.2: Power supply unit (SIPLACESX1/SX2 edition V2,
SMPS)
1. Main switch (S1)
2. Service socket (X98)
(up to machine no. P2038G)
3. Main power supply cable connection termi-
nals (X94) for the power supply cable
1 Introduction
50 Montageanleitung / Assembly Instructions WPC an/on SIPLACE SX1/SX2 - 03/2025
Machine switched off at the main power switch and disconnected
DANGER
Hazardous voltages in the power supply unit!
The power supply unit houses components (capacitors) that can carry hazardous voltages for about
five minutes after the machine has been switched off and the power plug has been unplugged.
Wait at least five minutes before your start working on the power supply unit and check for
absence of voltage (see Checking For Absence of Voltage).
Work on the power supply and the contactor safety breaker (CSB) must only be carried out by
service engineers of ASMPT SMT Solutions or by machine owner service engineers who have
been trained by ASMPT.
Compressed air conditions in the machine after switching off at the main switch
When the machine is switched off at the main power switch or if the power supply fails, the electrically-
controlled main valve of the compressed air unit closes. The pressure will drop to 0 MPa (0bar) within
five seconds.
1.1.5 Safety instructions for the compressed air supply
CAUTION
Risk of injury from compressed air!
Risk of injury when disconnecting the compressed air lines.
Never disconnect compressed air lines while they are still pressurized.
CAUTION
Prolonged interruptions to the compressed air supply can cause damage.
When the machine is switched on, do not use the shutoff valve to interrupt the compressed air supply
for more than 30 minutes.
If you need to shut off the compressed air system for longer in order to carry out your work, you
must switch the machine off at the main switch and disconnect it from the power supply.
1.1.6 Safety instructions for work on the cutting device
WARNING
Risk of injury when working near the cutter.
When working in the area of the tape cutter, move the component trolley out of the machine and dis-
connect the machine from the mains supply and the compressed air supply.
Wait until the operating pressure has dropped to 0 MPa.
Pull one of the hoses off the Y distributor on the cutter, to vent the pneumatic lines and the cut-
ters (see Venting compressed air at the cutter).
After completing work to the cutter, you will need to connect the hose again.
Always secure the machine against unauthorized reactivation.
Do not reach into the tape cutter.
CAUTION
Risk of injury when performing service work on the tape cutter.
Never support the tape cutter on your body, e.g. on your knees or thighs. Do not place your feet
under the tape cutter.
Wear appropriately thick protective gloves.
Only hold and carry the cutter on the outer left and righthand parts.