8 WF 4 TX-Series Maintenance Grease the guide bearing, clean the linear guide and scale of the Y-Axis 5 min 1 / 4 C A U T I O N ! R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c …

www.asm-smt.com

8 WF 4 TX-Series Maintenance Grease the guide bearing, clean the linear guide and scale of the Y-Axis 5 min 1 / 4
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T89
Wear Part: Consumables:
C3, C5, C49
www.asm-smt.com
1 Pull back the plunger to the lock. 2 Unscrew the top section. 3 Prepare the grease cartridge (if required).
4 Insert the grease cartridge into the grease
gun (if required).
5 Close the grease gun. 6 Mount the hose with hydraulic mouthpiece
Y-Axis.

8 WF 4 TX-Series Maintenance Grease the guide bearing, clean the linear guide and scale of the Y-Axis 5 min 2 / 4
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status OFF Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T89
Wear Part: Consumables:
C3, C5, C49
www.asm-smt.com
7 Loosen the lock. 8 Push back the ball on the vent screw. 9 Press the trigger until grease comes out.
10 Remove excess grease. 11 Mount the stroke limiter Y-Axis 0.4 gr side
of grease gun.
12 Move the gantry to possible working area.