19 WF 4 TX-Series Maintenance Calibrating the TH 14 min 8 / 9 C A U T I O N !  R e f e r t o s a f e t y i n s t r u c t i o n s i n u s e r m a n u a l b e f o r e c o m m e n c i n g M a i n t e n a n c e Machine Stat…

100%1 / 80
19 WF 4 TX-Series Maintenance Calibrating the TH 14 min 7 / 9
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T5
Wear Part: Consumables:
www.asm-smt.com
37 Click on "change with" icon. 38 Select the calibration nozzles and then
click on "OK" icon.
39 Select the second head TH if required.
40 Repeat the steps 35 to 39. 41 Click on "calibration" icon. 42 Click on "start" icon.
19 WF 4 TX-Series Maintenance Calibrating the TH 14 min 8 / 9
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T5
Wear Part: Consumables:
www.asm-smt.com
43 Press machine start if requested. 44 Calibration duration 5 mins. 45 Click on accept (1) and then on display
setup (2).
46 Click on all nozzles. 47 Click on return nozzles. 48 Select the second head TH if required.
19 WF 4 TX-Series Maintenance Calibrating the TH 14 min 9 / 9
CAUTION! Refer to safety instructions in user manual before commencing Maintenance
Machine Status ON Conveyor Empty
NOTICE! ESD guidelines are to be followed Tool:
T5
Wear Part: Consumables:
www.asm-smt.com
49 Repeat the steps 46 to 47 if required. 50 Push stop button. 51 Open cover.
52 Remove the calibration tool. 53 Close cover. 54 Press start.