1.9 Control Box Air Filter Cleaning (Every Month) Point If the air filter is clogged the effectiveness of the cooling fan will be reduced, and the temperature in the control box will rise. If the machine is operated in t…

100%1 / 56
1.8 Changing Index Unit Oil (Every Year)
Point
The index unit inside the cam box uses a lubrication oil. This lubrication oil is loaded in
the oil tank that is located on the left side of the machine.
Change this oil once every year.
Lubrication oil: Bonnok M150 Nippon Oil Company
Oil amount: 15 litres
Procedure
WARNING
Always be sure to cut off the main power before carrying out any work.
Before starting, prepare a container to receive the oil.
1. Remove the cover from around the oil tank.
2. Loosen the 2 drain plugs and drain the oil. Be careful not to spill the oil from the
container.
3. Tighten the 2 plugs then remove the cap from the top of the tank.
Slowly pour in the new oil (Bonnok M150).
4. Add sufficient oil to return it to its initial level. The oil gage is between the oil tank
and the cam box.
Lid
Drain plugs
Index unit
Rear view
Cam box
Add sufficient oil to return it
to its initial level
Oil tank
CP6ML006E
Chapter 4 Cleaning and Lubrication
Version 11.1 4-1-8 CP-6 Series Maintenance
1.9 Control Box Air Filter Cleaning (Every Month)
Point
If the air filter is clogged the effectiveness of the cooling fan will be reduced, and the
temperature in the control box will rise. If the machine is operated in this condition there
is a danger that the servo amplifiers and VME board will not function correctly.
In order to prevent clogging, clean off dust and dirt every month.
Chapter 4 Cleaning and Lubrication
Version 11.1 4-1-9 CP-6 Series Maintenance
1.10 Cleaning the Filter Regulator (Every Week)
Point
The air flowing within the pneumatic piping needs to be clean at all times.
A dirty filter element may make it impossible to supply clean air and lead to equipment
breakdown.
Procedure
WARNING
Always be sure to cut off the main power before carrying out any work.
Hold down the lock knob and remove the filter case. Wash the filter case with a mild,
non-alkaline detergent.
Note: The element should be replaced every two years.
O-ring
Element
Lock knob
Filter case
O-ring
Element
Lock knob
Filter case
CP6ML007E
Chapter 4 Cleaning and Lubrication
Version 11.1 4-1-10 CP-6 Series Maintenance