00196624-04_Service Manual WPC5_6_EN_01-2019.pdf - 第36页

Service Ma nual W PC5 / WPC6 ➢ Fasten the new motor t o the motor flange and f ollow the instruction s for removal in rever se order. ➢ Support the motor from below and loosen the screws fastening the motor flange at the…

100%1 / 143
Service Manual WPC5 / WPC6
Removal / Installation
The load unit drive motor is located under the base plate of the load unit.
Remove the cover on the load unit (see "3.5.1.1 Remove the Cover on the Load Unit" [ 3-
32]).
Loosen the belt tension of the load axis (see "3.5.1.4 Loosen the Tension of the Load Axis
Drive Belt" [ 3-33]).
Loosen the screws fastening the motor to the base
plate and the plastic rail (1).
Pull the motor a little to the front, until you have
access to the electrical connections on the left side.
Loosen the two screws fastening the electrical
connections.
X1 orange cable = power cable
X2 green cable = control cable
Remove the motor. Make sure that the belt is not
bent or damaged.
Service Manual WPC5 / WPC6
Fasten the new motor to the motor flange and follow the instructions for removal in reverse
order.
Support the motor from below and loosen the
screws fastening the motor flange at the points
marked 1 to 3..
NOTICE
Screw joints difficult to loosen
Each screw joint has an O-ring seal. This can make opening the screw joint difficult.
Use a pair of water pump pliers to help you unscrew the connection.
Make sure that the O-rings do not fall out of the screw joint and that they are not damaged.
Service Manual WPC5 / WPC6
3.5.3 Replace the Load Axis Drive Toothed Belt
When installing the motor, make sure that it is aligned parallel to the slide bar.
Readjust the belt tension (see "3.5.6 Setting the Load Axis Belt Tension" [ 3-43]).
Spare Part
Toothed belt 10T5/1640 E [03053795-xx]
Preparations
Move the tower into the refill position.
Remove all waffle pack tray carriers (WPTCs) from the tower.
Move the tower downwards.
Undock the WPC from the SIPLACE machine and move it to a suitable position for service
work.
Switch the WPC off at the main switch.
Unplug from the power supply and secure the WPC to prevent unauthorized reactivation.
Remove the cover from the non-stop module (see "3.5.1.1 Remove the Cover on the Load
Unit" [ 3-32]).
Remove the hand guard from the feed axis (see "3.5.1.2 Removing the Right Side Cover
from the WPC" [ 3-32]).