00196624-04_Service Manual WPC5_6_EN_01-2019.pdf - 第61页
Service Ma nual W PC5 / WPC6 3.6.4.3 Po wer Suppl y W PC6 1 Inrush current lim itation board W PC NS [03056232-xx] 11 End plate, gray, type 282 -311 [00372782 -xx] 2 Inrush current lim itation board W PC [03047752-xx] 12…

Service Manual WPC5 / WPC6
3.6.4.2 Power supply WPC5
1
Inrush current limitation board WPC
[03047752-xx]
7
Cable duct 40X40mm GYT1-40X40
[03008823-xx]
2
Contactor 3RT10 15-2BM42 [03048357-xx]
discontinued,
Contact. 3RT2 AC3 1NC DC220V 3p
[03171139-xx] successor, K4
8
Contactor 3RT10 15-1BB42 [03048563-
xx] discontinued,
Contactor 3RT2 AC3 1NC DC24V 3p
[03171138-xx] successor, K2 and K3
3
Suppression diode for contactors DC150-
250V [03048925-xx]
9
Suppression diode for contactors DC 24-
70V [00342396S01]
4 Transformer WPC5 [03057556-xx] 10
Auxil. switch block 3RH19 / 2 POL 1Ö+1S
[03048564-xx] discontinued,
Auxiliary switch block 3RH2 1NC + 1NO
[03171137-xx] successor; on K3
5
Line filter for 3-phase system 10A
[03048582-xx]
11
Emergency stop switchgear 3TK2828-
1BB41 [00372649-xx], K1
6 Rectifier bridge 800V / 25A [03048868-xx]
For a detailed overview of the connections, see "3.7.1.3 Detailed Connections for Limit Switches,
Sensors and Light Barriers" [➙ 3-71].

Service Manual WPC5 / WPC6
3.6.4.3 Power Supply WPC6
1
Inrush current limitation board WPC NS
[03056232-xx]
11 End plate, gray, type 282-311 [00372782-xx]
2
Inrush current limitation board WPC
[03047752-xx]
12 Transformer WPC5 [03057556-xx]
3
Contactor 3RT10 15-2BM42 [03048357-
xx], K4
13
Line filter for 3-phase system 10A [03048582-
xx]
4
Suppression diode for contactors DC150-
250V [03048925-xx] discontinued
,
Surge suppressor diode 3RT2 150-250V
LED [03171141-xx] successor; on K4
14 Rectifier bridge 800V / 25A [03048868-xx]
5
Ground terminal block 4-cond 280-677
[00323829-xx]
15
Cable duct 40X40mm GYT1-40X40
[03008823-xx]
6
Through terminal block GY 4-con. 280-
633 [00323828-xx]
16
Contactor 3RT10 15-1BB42 [03048563-xx],
K2 und K3
7
Adjacent jumper 280-402 [0035338-xx]
17
Suppression diode for contactors DC 24-70V
[00342396Sxx]
discontinued
,
Surge suppressor diode 3RT2 24V-70V LED
[03171140-xx] successor; on K3
8
End plate 2.5mm orange 280-315
[00323836-xx]
18
Auxil. switch block 3RH19/2pole/1NC+1NO
[03048564-xx], on K3
9
Screwless end stop 6 m 249-116
[00356396-xx]
19
Emergency stop switchgear 3TK2828-1BB41
[00372649-xx], K1
10
Fuse clamp 10A (6.3X32) 282-128
[00372781-xx]
20
Emergency-Stop and protective door
monitoring [03056745-xx], K5 and K6
For a detailed overview of the connections, see "3.7.1.3 Detailed Connections for Limit Switches,
Sensors and Light Barriers" [➙ 3-71].

Service Manual WPC5 / WPC6
Non-Stop-Module Elektrics [03057797-xx]
Parts
Quantity
Name
Item no.
1
Table
plate electrics
03
0
5
7
79
8
-
xx
1
Power cable load axis
03
0
5
6
95
0
-
xx
1
Signal cable load axis
03
0
5
6
94
8
-
xx
1
Reference point proximity switch load axis
03
0
5
6
94
7
-
xx
1 ble: operat. button with signal light 03057602-xx
1 Cable: Safety sensor loading flap 03057600-xx
1 Cable: safety sensor hand guard 03057601-xx
1 Cable: lifting magnet safety flap closing 03057603-xx
1 Cable: lifting magnet safety flap opening 03057604-xx
1 Crash light barrier normal components load
axis
03057012-xx
1
Crash light barrier hi
gh components load axis
03
0
5
7
29
1
-
xx
1
Cable:
sensor safety flap open
03
0
5
7
59
8
-
xx
1
Cable: sensor tray correctly inserted
03
0
5
7
59
9
-
xx
1
Cable: sensor tray detection load axis
03
0
7
1
45
3
-
xx