00196624-04_Service Manual WPC5_6_EN_01-2019.pdf - 第63页

Service Ma nual W PC5 / WPC6 3.6.5 Power Supply Unit 3.6.5.1 Repla cing the Prote ctive Co ntacto r Combina tio n (SSK ) Spare Part • Protective contactor com bination (SSK) 3TK2828 - 1BB41 [0 0372649-xx] Removal / Insta…

100%1 / 143
Service Manual WPC5 / WPC6
Non-Stop-Module Elektrics [03057797-xx]
Parts
Quantity
Name
Item no.
1
Table
plate electrics
03
0
5
7
79
8
-
xx
1
Power cable load axis
03
0
5
6
95
0
-
xx
1
Signal cable load axis
03
0
5
6
94
8
-
xx
1
Reference point proximity switch load axis
03
0
5
6
94
7
-
xx
1 ble: operat. button with signal light 03057602-xx
1 Cable: Safety sensor loading flap 03057600-xx
1 Cable: safety sensor hand guard 03057601-xx
1 Cable: lifting magnet safety flap closing 03057603-xx
1 Cable: lifting magnet safety flap opening 03057604-xx
1 Crash light barrier normal components load
axis
03057012-xx
1
Crash light barrier hi
gh components load axis
03
0
5
7
29
1
-
xx
1
Cable:
sensor safety flap open
03
0
5
7
59
8
-
xx
1
Cable: sensor tray correctly inserted
03
0
5
7
59
9
-
xx
1
Cable: sensor tray detection load axis
03
0
7
1
45
3
-
xx
Service Manual WPC5 / WPC6
3.6.5 Power Supply Unit
3.6.5.1 Replacing the Protective Contactor Combination (SSK)
Spare Part
Protective contactor combination (SSK) 3TK2828-
1BB41 [00372649-xx]
Removal / Installation
Label all connections for easier installation later.
Unplug all connections from the protective contactor combination.
Lever the protective contactor combination off the mounting rail.
Connect the new protective contactor combination to the mounting rail and restore the
electrical connections..
Settings
Adjust the setting screw (1) to a value of 0.5 (seconds). If the value is set too high, an error
message will be issued.
Seal the setting screw with locking varnish.
The protective contactor combination (SSK) is
located at the front of the electrical unit (see "3.6.2
Overview"[ 3-46]).
1. setting screw
Service Manual WPC5 / WPC6
3.6.5.2 Replacing the Emergency STOP and Protective Door Monitor (WPC6 only)
Spare Part
Emergency STOP and guard door monitor [03056745-xx]
Removal / Installation
Label all connections for easier installation later.
Unplug all connections from K5/K6.
Lever the K5/K6 off the mounting rail.
Connect the new K5/K6 to the mounting rail and restore the electrical connections.
1. Protective door monitor and
emergency STOP, K5 and K6
2. SSK K1
3. Contactor K 2
4. Contactor K 3