00196624-04_Service Manual WPC5_6_EN_01-2019.pdf - 第63页
Service Ma nual W PC5 / WPC6 3.6.5 Power Supply Unit 3.6.5.1 Repla cing the Prote ctive Co ntacto r Combina tio n (SSK ) Spare Part • Protective contactor com bination (SSK) 3TK2828 - 1BB41 [0 0372649-xx] Removal / Insta…

Service Manual WPC5 / WPC6
Non-Stop-Module Elektrics [03057797-xx]
Parts
Quantity
Name
Item no.
1
Table
plate electrics
03
0
5
7
79
8
-
xx
1
Power cable load axis
03
0
5
6
95
0
-
xx
1
Signal cable load axis
03
0
5
6
94
8
-
xx
1
Reference point proximity switch load axis
03
0
5
6
94
7
-
xx
1 ble: operat. button with signal light 03057602-xx
1 Cable: Safety sensor loading flap 03057600-xx
1 Cable: safety sensor hand guard 03057601-xx
1 Cable: lifting magnet safety flap closing 03057603-xx
1 Cable: lifting magnet safety flap opening 03057604-xx
1 Crash light barrier normal components load
axis
03057012-xx
1
Crash light barrier hi
gh components load axis
03
0
5
7
29
1
-
xx
1
Cable:
sensor safety flap open
03
0
5
7
59
8
-
xx
1
Cable: sensor tray correctly inserted
03
0
5
7
59
9
-
xx
1
Cable: sensor tray detection load axis
03
0
7
1
45
3
-
xx

Service Manual WPC5 / WPC6
3.6.5 Power Supply Unit
3.6.5.1 Replacing the Protective Contactor Combination (SSK)
Spare Part
• Protective contactor combination (SSK) 3TK2828-
1BB41 [00372649-xx]
Removal / Installation
➢ Label all connections for easier installation later.
➢ Unplug all connections from the protective contactor combination.
➢ Lever the protective contactor combination off the mounting rail.
➢ Connect the new protective contactor combination to the mounting rail and restore the
electrical connections..
Settings
➢ Adjust the setting screw (1) to a value of 0.5 (seconds). If the value is set too high, an error
message will be issued.
➢ Seal the setting screw with locking varnish.
The protective contactor combination (SSK) is
located at the front of the electrical unit (see "3.6.2
Overview"[➙ 3-46]).
1. setting screw

Service Manual WPC5 / WPC6
3.6.5.2 Replacing the Emergency STOP and Protective Door Monitor (WPC6 only)
Spare Part
• Emergency STOP and guard door monitor [03056745-xx]
Removal / Installation
➢
➢
➢
➢
➢
➢
➢
➢
➢
➢
➢ Label all connections for easier installation later.
➢ Unplug all connections from K5/K6.
➢ Lever the K5/K6 off the mounting rail.
➢ Connect the new K5/K6 to the mounting rail and restore the electrical connections.
1. Protective door monitor and
emergency STOP, K5 and K6
2. SSK K1
3. Contactor K 2