Technical Data of the SIPLACE JTF-MW Electrical Data 3.1.1 Location of Electrical Parts 26 User Manual JTF-MW on SIPLACE E

Technical Data of the SIPLACE JTF-MW
3.1.1 Location of Electrical Parts Communication, Signals
User Manual JTF-MW on SIPLACE E 25
3.5
3.5 Communication, Signals
Communication, Signals
3.6
3.6 Ambient Conditions
Ambient Conditions
3.7
3.7 Electrical Data
Electrical Data
Electrical components, motors, sensors and buttons, etc. are integrated in the SIPLACE JTF-MW.
It consists of the following functional blocks:
Functional diagram of electrical system in the SIPLACE JTF-MW
Communication interface ASM pogo pin interface, CAN bus
Ambient conditions Description
Relative humidity 30% to 75 % (no higher than 45% on average to
prevent any possibility of condensation on the ma-
chine)
Temperature 10 °C to 35 °C / 50 °F to 95 °F
Power consumption
Peak 5 A
Standby 1 A
During tray exchange 1.3 A
Fuse 1.85 A
Voltage supply 24 VDC ± 10%
Technical Data of the SIPLACE JTF-MW
Electrical Data 3.1.1 Location of Electrical Parts
26 User Manual JTF-MW on SIPLACE E

Setting up and Commissioning
Scope of Delivery
User Manual JTF-MW on SIPLACE E 27
4
4 Setting up and Commissioning
Setting up and Commissioning
4.1
4.1 Scope of Delivery
Scope of Delivery
The scope of delivery includes the following parts:
Not included are all options like power supplies, mount plates etc. and other accessories for custom ad-
aptation.
4.2
4.2 Unpacking and Checking the Delivery
Unpacking and Checking the Delivery
The JTF-MW is put in a one way crate made of carton.
► After receiving the delivery, check the feeder for transportation damages.
Transportation damages are to be reported with photos and proves directly to the forwarder.
► Other claims are to be reported to ASM within 14 days of receipt of the feeder. For details, refer to
"1.1.1 Warranty" [ ➙ 5]
► Contact ASM to get an RMA number if replacement parts are needed.
► During removal, remember that the SIPLACE JTF-MW (~ 60 kg/~ 132 lb) is heavy. You might need
to enlist the help of a second person.
► Make sure a solid table is available right next to the open crate, to put the feeder on it.
► If you put the feeder in stock, refer to "4.3 Storage" [ ➙ 27].
4.3
4.3 Storage
Storage
In case the feeder is not used after receipt and put in a ware house, please make sure the feeder is in
an upright position. If you are unsure if the feeder is upright, open the crate and check.
The storage location shall be clean and the temperature shall be between -25 °C and +55 °C at a relative
humidity of less than 45% on average.
After storage, the feeder shall be conditioned according to the environmental temperature and humidity
for at least 48 hours (between 15 °C and 25 °C).
Part number Description
03118894-xx SIPLACE JTF-MW feeder, preassembled
03115273-xx JTF-MW table kit
03117595-xx JTF-MW frame kit
03120613-xx Tubing set for JTF-MW
03110329-xx Shortened empty tape duct, ETD 25 mm right
CAUTION
Heavy Weight
The heavy weight of the SIPLACE JTF-MW (~ 60 kg/~132 lb) could cause injuries if the module
is not handled correctly.
► Do not lift or carry the module alone.
► Use lifting aids and proper lifting techniques when removing or replacing.
► You might need to enlist the help of a second person.