Tasks on the Machine Operating the JEDEC Tray Feeder in the Station Software (SW708) User Manual JTF-MW on SIPLACE E 51 Position Correction If necessary, perform a pickup p osition correction for the sele cted tray. ▪ Te…

100%1 / 68
Tasks on the Machine
Operating the JEDEC Tray Feeder in the Station Software (SW708)
50 User Manual JTF-MW on SIPLACE E
Filling Level Functions for the Selected Tray (3)
Change filling level - pocket 134
The current filling level displays pockets 1 to 134 as occupied. Pockets 135 to 160 are displayed as emp-
ty.
Button
Activate Currently without information or function.
Set Full Sets the selected tray to full (every component in the tray is
displayed in gray color).
Set Empty Sets the selected tray to empty (every component in the tray
is displayed in white color)
Change Filling Level Opens a virtual tray. You can directly select the last occupied
pocket of the tray that contains a component.
An arrow represents the numbering direction that also corre-
sponds to the pickup direction.
The transfer position is always at the top.
In the following example, pocket 134 is selected as the pocket
that contains the last component. Pockets 135 to 160 shall be
empty.
Please note that the selected pocket is difficult to recognize.
Tasks on the Machine
Operating the JEDEC Tray Feeder in the Station Software (SW708)
User Manual JTF-MW on SIPLACE E 51
Position Correction
If necessary, perform a pickup position correction for the selected tray.
Teaching the pickup position for eccentric pickup.
Teaching the component center
Switching to Level View
Press the change button to display the level view of the SIPLACE JTF-MW.
1. Position of the SIPLACE JTF-MW tray
2. State (2) indicates that a tray is present on this level which is not used for this setup. The filling level
is not queried.
3. Filling level: Actual - target
4. Component: Component description
5. Component shape: Component shape name
Single Tray Selection
The line for a single selected tray is highlighted in blue color.
Use the cursor to select a single tray.
You can now make settings for the tray and assign different states.
Please note that the trays have been selected in advance in the example in the screenshot.
1. Set empty: Sets the tray to "Out of components". Use the Set full button to set it back to full.
Tasks on the Machine
Operating the JEDEC Tray Feeder in the Station Software (SW708)
52 User Manual JTF-MW on SIPLACE E
2. Deactivate: Deactivates the complete tray which is then marked as "Deactivated by operator". Use
the Activate button to set it back to active.
You can select the following functions and actions for the single selected tray:
1. Selected tray: highlighted in blue color
2. Provide level: Moves this level to the transfer position.
3. Correct position: Correction of the pickup position
4. Move to refill position: Moves the tray back into the tray carrier in order to remove it. In this state, no
components can be picked up from any tray.
5. FIFO strategy: This button is active when you are logged in with the necessary access privileges. As
soon as pickup has been performed once from a JEDEC tray on a replacement track, this will be
emptied completely before the actual track is used again.
Multiple Selection of Trays
Use the key combination Shift+Alt to select several trays. The selected trays are then highlighted in blue
color.
If trays have been deactivated manually or automatically before or if the state has been changed, you
can now easily select these trays with the Selection button.