00197961-01_UM_JTF-MW_on_SIPLACE_E_en_FINAL.pdf - 第34页

Setting up and Commissioning Installation and Commissioning the SILPACE E 34 User Manual JTF-MW on SIPLACE E JTF-MW in SIPLACE E machine ► Remove all JEDEC trays from JTF-MW to reduce the weigh t. ► Toge ther with a seco…

100%1 / 68
Setting up and Commissioning
Installation and Commissioning the SILPACE E
User Manual JTF-MW on SIPLACE E 33
Installing the Frame Kit
The frame kit acts as a stop and prevents the JTF-MW from tilting.
4.6
4.6 Installation and Commissioning the SILPACE E
Installation and Commissioning the SILPACE E
4.6.1
4.6.1 Installing the JTF-MW in the Machine
Installing the JTF-MW in the Machine
Install the frame kit (1) at its installation position on
the left of the empty tape duct.
Fix it at the two fixation points (2).
COT in loading position
Move the COT table to the loading position so that the
table is in a fixed position when installing the
JTF-MW.
Setting up and Commissioning
Installation and Commissioning the SILPACE E
34 User Manual JTF-MW on SIPLACE E
JTF-MW in SIPLACE E machine
Remove all JEDEC trays from JTF-MW to reduce the
weight.
Together with a second person, lift the JTF-MW by its
handle and carry it to the machine.
Position the JTF-MW on tracks 1 to 30.
Slide the JTF-MW into the machine (1) until the stop
at the frame kit.
JTF-MW fixed at COT
Fix the JTF-MW at the indicated positions to the COT
using two washers (ISO 7092 5) and two M5x20
screws (ISO 4762).
Setting up and Commissioning
Configuration of SIPLACE JTF-MW in SIPLACE Pro
User Manual JTF-MW on SIPLACE E 35
4.6.2
4.6.2 Connecting the JTF-MW to the Machine
Connecting the JTF-MW to the Machine
The SIPLACE JTF-MW powers up and initializes. After that, you can operate the SIPLCE JTF-MW via
its control panel (see "5.2 Controls and Displays on the Feeder Control Panel" [ ➙ 41]).
After the COT has been loaded, the control is transferred to the station software and you can operate
the SIPLACE JTF-MW via the station software (see "5.5 Operating the JEDEC Tray Feeder in the Station
Software (SW708)" [ ➙ 46]).
The stop button and the reset button on the control panel are still available.
4.7
4.7 Configuration of SIPLACE JTF-MW in SIPLACE Pro
Configuration of SIPLACE JTF-MW in SIPLACE Pro
SIPLACE JTF-MW feeders are available from SIPLACE Pro 12.0.
Connecting the JTF-MW
Connect the power cable of the SIPLACE JTF-MW to
the Harting connector at the host machine (1).
Connect the pneumatic tube from the SIPLACE
JTF-MW (2) to the coupling at the host machine (3).