Installation Manual, Station Software Version 701.02 07/2008 Edition 3.3 Network configuration Fig. 3-2: Network connections between the machine and SIPLACE Pro A separate private network (100 Mbit/s) is set up between t…

Installation Manual, Station Software Version 701.02 07/2008 Edition
13 of 38
3.2.1 Machine computer
Name
SIMATIC Box PC 627
CPU / clock frequency
Pentium M 760 / 2 GHz
RAM
1 GB
Hard disk
Yes
External compact flash drive
Yes
External DVD drive
Yes (1 per machine)
Serial interfaces
1
USB interfaces and external USB hub
Yes
Network
2x 100 MBit
Table 3-1: Machine computer hardware
3.2.2 Vision computer
Name
SIMATIC Box PC 627
CPU / clock frequency
Pentium M 760 / 2 GHz
RAM
1 GB
Hard disk
Yes
External compact flash drive
Yes
External DVD drive
Yes (1 per machine)
Serial interfaces
1
USB interfaces and external USB hub
Yes
Network
2x 100 MBit
Table 3-2: Vision computer hardware

Installation Manual, Station Software Version 701.02 07/2008 Edition
3.3 Network configuration
Fig. 3-2: Network connections between the machine and SIPLACE Pro
A separate private network (100 Mbit/s) is set up between the machine computer and the Vision computer
via a subnet mask.
Fixed IP addresses for the machine computer and the Vision computer can thus be assigned for all
SIPLACE machines. These IP addresses are not known outside the private network, for instance in the
SIPLACE LAN or customer LAN.
These IP addresses need not be further configured by the operator while the station software is being
installed.
14 of 38

Installation Manual, Station Software Version 701.02 07/2008 Edition
4 Installing the machine computer
4.1 Installation sequence
See section
4.2.
15 of 38
See section
4.3.
See separate Installation Manual for details on installing the
Windows XP operating system (item no. 00194575-xx)
4.4.3.
For details on calibrating the touchscreen, see section