4 在您打开包 装之后, 请先按照下 面的清单 对照包装 箱内的东西 是否齐全。 万一发现有 不良或缺 少的产品, 以及使用 说明书中 的漏页,错 页等请与本 公司联系。 1. □ PCU-2 85 本体装 置 1 台 2. □ 内筒 1 个 3. □ 外筒 ( 附叶 片 ) 1 个 4. □ 电源线 ( 附 适配器 ) 1 根 5. □ 塑料刮刀 1 个 6. □ 清洗刷 1 个 7. □ 外筒用筒内 清洁棒 1 个 8. □ PCU…

3
5 – 2 准备打印用纸 ························································································· 36
5 – 3 打印测试 ······························································································· 37
5 – 4 HEX打印 ···························································································· 37
5 – 5 LED表示 ···························································································· 38
6 锡膏粘度的测定例 ························································································· 39
7 测定结束后的清扫 ························································································· 42
Ⅲ.保养・售后服务
1 使用上的注意 ······························································································· 44
2 保管 ············································································································ 44
3 校正・定期点检 ···························································································· 44
4 关于修理······································································································ 45
5 选件・配件 ·································································································· 46
5 - 1 备有以下选件和配件 ················································································ 46
5 – 2 使用少量试料进行测定 ············································································· 46
Ⅳ.附录
1 外形尺寸图 ·································································································· 48
2 故障检测······································································································ 49
3 旋转数-粘度测定界限图 ················································································ 54
4 如何正确使用粘度计 ······················································································ 55
4 - 1 关于粘度 ······························································································· 55
4 – 2 试料······································································································ 57
4 – 3 温度······································································································ 58
4 – 4 装置······································································································ 59
4 – 5 旋转粘度计精度的检查 ············································································· 59
4 – 6 换算表(KF-96H) ··················································································· 60
5 致购买 200V 规格(含 220V 和 240V 规格)的用户 ···················································· 61

4
在您打开包装之后,请先按照下面的清单对照包装箱内的东西是否齐全。
万一发现有不良或缺少的产品,以及使用说明书中的漏页,错页等请与本公司联系。
1. □ PCU-285 本体装置 1台
2. □ 内筒 1个
3. □ 外筒(附叶片) 1个
4. □ 电源线(附适配器) 1根
5. □ 塑料刮刀 1个
6. □ 清洗刷 1个
7. □ 外筒用筒内清洁棒 1个
8. □ PCU-285 使用说明书 1部
9. □ 保证书 1部
10. □ 粘度评价系统 粘度评价〈VAM-5〉 1套
11. □ USB 线(A B 规格) 1根
〈打印机选配〉
12. □ 打印用纸 1卷
〈当选配里 恒温槽选择变更为300cc时〉
选择300cc的恒温槽时,附属品作如下变更。
・恒温槽为300cc恒温槽
3. □ 外筒(附 300cc 专用叶片) 1个
・300cc恒温槽和铝适配器(AD-300 等)
3. □ 外筒(附 100cc 用叶片) 1个
(和通常品一样)
13. □ 铝适配器(AD-300 等) 1组
PCU-285
PCU-285PCU-285
PCU-285包装清单
包装清单包装清单
包装清单

5
使用注意
使用注意使用注意
使用注意
因为容易伤手,所以请不要紧握内筒的螺旋槽部位。
请小心使用。
请不要拆卸本仪器。以免产生故障、漏电等。
安装内筒时请不要使用工具。
不要用太强的力道去拧紧。(
6.9kg・cm 以下
)
请注意不要让试料进入到传感器部。
测定结束后,请将内·外筒清洗干净,否则试料会凝固在传感器上,造成仪器无
法正常运转。
请定期对仪器进行校正。
外筒在旋转时,请不要将手指等放进去。以免受伤。
本装置和粘度传感器(内外筒)是采用一体化进行粘度校正的。如果使用其他的粘度传感器
(内外筒)会引起粘度值起偏差、影响测定结果、请勿使用。如要使用其他内外筒进行测定,
需再次进行粘度值的校正。