Queue-Inspection-Manual-REV-G-2.pdf - 第16页

Queue/In spectio n Revision G / January 2022 Page 16 of 21 Fault Recovery Pro cedure Warning : If t he Emergency Stop was e ngaged because of sy stem failure, do not disengage the Emergency Stop button. Shutdown the syst…

100%1 / 21
Queue/Inspection
Revision G / January 2022
Page 15 of 21
Inspection Module
When the inspection module operates as an inspection/transfer station, auto cycle operates
as follows:
1. The inspection module sends a ready signal to the upstream process that it can
accept a board.
2. A signal from the upstream process that a board is available or a signal from the
upstream sensor starts the conveyor.
3. If there is no upstream process the board will be manually loaded.
4. When the upstream sensor is triggered, the ready signal to the upstream process (if
present) is stopped.
5. If the Bypass switch is off, the board will move to the inspection sensor and stop.
6. Remove the board for inspection or leave it on the conveyor.
7. After inspection is complete, push the continue button.
8. The board shuttles to the downstream sensor unless the Emergency Stop button is
engaged.
9. A signal is sent to the downstream process (if present) that a board is available.
10. If the downstream process is ready, the board will move out of the inspection module.
11. If the downstream process is not ready the board will stop on the downstream sensor
until a ready signal is received, or the board is removed.
12. When the downstream sensor is cleared, the board available signal to the downstream
process (if present) is stopped.
13. The cycle then starts again.
Queue/Inspection
Revision G / January 2022
Page 16 of 21
Fault Recovery Procedure
Warning: If the Emergency Stop was engaged because of system failure, do not
disengage the Emergency Stop button. Shutdown the system and have qualified
personnel repair the machine.
Recovery Procedure
For all errors that activate the buzzer do the procedure that follows, to return the module to
operation.
1. Remove all boards from the module.
2. Engage the Emergency Stop button.
3. Disengage the Emergency Stop button.
Queue/Inspection
Revision G / January 2022
Page 17 of 21
Troubleshooting
Some problems are easy to identify and solve, for others more help may be necessary. This
section is to assist in solving problems before you seek additional help. Refer to this section
if a mechanical or electrical problem occurs.
Calling Technical Support
The technical support staff is always available to help solve any problems. The phone
number is +1-518-371-2684. Have the following information before calling for help:
The operation in progress when the machine had trouble (when did it have problems,
what was it doing, etc.).
If the error was not serious, attempt to repeat the error. If the error does not repeat,
the problem may have been operator generated.