161页面.pdf - 第173页
N o n s tanda r d Cam sw itch es and Sw itch- dis co nnec t ors TM Non -st andard swi tches - SOND Ra te d current Nu mbe r of c ont ac t chambers Mounting option Main swi tch Par t number Ar ticle number Su it abl e fo …

Non standard Cam switches and Switch-disconnectors
T5 Cam switches
Rated
current
Number of contact
chambers Mounting option
Main
switch
Handle
colour Part number
Article
number
Suitable for
export to North
America (US
and Canada)
100 A 5
Flush mounting Red T5-5-SOND*/E 907982
Flush mounting
Red T5-5-SOND*/EA/SVB 908991
Flush mounting
Black T5-5-SOND*/EA/SVB-SW 908130
Rear mounting
Red T5-5-SOND*/V/SVB 908007
Rear mounting
Black T5-5-SOND*/V/SVB-SW 908138
Rear mounting Red T5-5-SOND*/Z 908025
6 Flush mounting Red T5-6-SOND*/E 907983
Flush mounting
Red T5-6-SOND*/EA/SVB 908992
Flush mounting
Black T5-6-SOND*/EA/SVB-SW 908131
Rear mounting
Red T5-6-SOND*/ V/SVB 908008
Rear mounting
Black T5-6-SOND*/V/SVB-SW 908139
Rear mounting Red T5-6-SOND*/Z 908026
7 Flush mounting Red T5-7-SOND*/E 907984
Flush mounting
Red T5-7-SOND*/EA/SVB 908993
Flush mounting
Black T5-7-SOND*/EA/SVB-SW 908132
Rear mounting
Red T5-7-SOND*/ V/SVB 908009
Rear mounting
Black T5-7-SOND*/V/SVB-SW 908140
Rear mounting Red T5-7-SOND*/Z 908027
8 Flush mounting Red T5-8-SOND*/E 907985
Flush mounting
Red T5-8-SOND*/EA/SVB 908994
Flush mounting
Black T5-8-SOND*/EA/SVB-SW 908133
Rear mounting
Red T5-8-SOND*/V/SVB 908010
Rear mounting
Black T5-8-SOND*/V/SVB-SW 908141
Rear mounting Red T5-8-SOND*/Z 908028
9 Flush mounting Red T5-9-SOND*/E 907986
Flush mounting
Red T5-9-SOND*/EA/SVB 908029
Flush mounting
Black T5-9-SOND*/EA/SVB-SW 907987
Rear mounting
Red T5-9-SOND*/V/SVB 908030
Note: Please use the ‘Ordering non-standard contact sequences’ order form when ordering for the first time. When placing repeat
orders, specifiy the contact sequence number together (e.g. 47110GB).
For Standard information please refer to pages 180 and 181
172
EATON P Switch-disconnectors and T Rotary cam switches CA042001EN

Non standard Cam switches and Switch-disconnectors
TM Non-standard switches - SOND
Rated
current
Number of contact
chambers Mounting option
Main
switch Part number
Article
number
Suitable for
export to North
America (US
and Canada)
10 A 1
Flush mounting TM-1-SOND*/E 907749
2 Flush mounting TM-2-SOND*/E 907763
3 Flush mounting TM-3-SOND*/E 907750
4 Flush mounting TM-4-SOND*/E 907751
5 Flush mounting TM-5-SOND*/E 907764
6 Flush mounting TM-6-SOND*/E 907752
7 Flush mounting TM-7-SOND*/E 907753
8 Flush mounting TM-8-SOND*/E 907754
1 Centre mounting TM-1-SOND*/E 907755
2 Centre mounting TM-2-SOND*/EZ 907756
3 Centre mounting TM-3-SOND*/EZ 907757
4 Centre mounting TM-4-SOND*/EZ 907758
5 Centre mounting TM-5-SOND*/EZ 907759
6 Centre mounting TM-6-SOND*/EZ 907760
7 Centre mounting TM-7-SOND*/EZ 907761
8 Centre mounting TM-8-SOND*/EZ 907762
1 Service distribution board TM-1-SOND*/IVS 225346
2 Service distribution board TM-2-SOND*/IVS 225348
For repeat orders for which the design number is already known Form F02 is not required for this purpose. The design number is
a six-digit number and must always be greater than 200000.
TM Non-standard switches - SOND-ERSTBESTELLUNG
Rated
current
Number of contact
chambers Mounting option
Main
switch Part number
Article
number
Suitable for
export to North
America (US
and Canada)
10 A 1
Flush mounting TM-1-SOND-ERSTBESTELLUNG/E 208261
1 Centre mounting TM-1-SOND-ERSTBESTELLUNG/EZ 208262
1 Service distribution board TM-1-SOND-ERSTBESTELLUNG/IVS 225347
2 Flush mounting TM-2-SOND-ERSTBESTELLUNG/E 208263
2 Centre mounting TM-2-SOND-ERSTBESTELLUNG/EZ 208264
2 Service distribution board TM-2-SOND-ERSTBESTELLUNG/IVS 225349
3 Flush mounting TM-3-SOND-ERSTBESTELLUNG/E 208265
3 Centre mounting TM-3-SOND-ERSTBESTELLUNG/EZ 208266
4 Flush mounting TM-4-SOND-ERSTBESTELLUNG/E 208267
4 Centre mounting TM-4-SOND-ERSTBESTELLUNG/EZ 208268
5 Flush mounting TM-5-SOND-ERSTBESTELLUNG/E 208269
5 Centre mounting TM-5-SOND-ERSTBESTELLUNG/EZ 208270
6 Flush mounting TM-6-SOND-ERSTBESTELLUNG/E 208271
6 Centre mounting TM-6-SOND-ERSTBESTELLUNG/EZ 208272
7 Flush mounting TM-7-SOND-ERSTBESTELLUNG/E 208273
7 Centre mounting TM-7-SOND-ERSTBESTELLUNG/EZ 208274
8 Flush mounting TM-8-SOND-ERSTBESTELLUNG/E 208275
8 Centre mounting TM-8-SOND-ERSTBESTELLUNG/EZ 208276
For new orders with a completed form
For Standard information please refer to pages 180 and 181
173EATON P Switch-disconnectors and T Rotary cam switches CA042001EN

Non standard Cam switches and Switch-disconnectors
Ordering of non standard contact sequences
T.......... - .............................................. - .................................. / ............................................................... + ..................
Switch
size
Number of contacts units
(2 contacts per contact unit)
Contact sequence number Mounting form Accessories
Max units Contacts max. With country ID corresponding to the
country of manufacture.
Send completed forms (as shown page
175) if ordering for the first time. The
contact sequence number is specified
by the supplying factory. Specifying the
part no is enough when placing repeat
orders.
Flush mounting: /E Always specify
completely for
every order
For TM.../EZ
only +EZ/S
possible
TO 11 22 Centre mounting: /EZ (for T0, T3)
T3 11 22 Surface mounting: /I
(1)
T5B 10 20 Service distribution board mounting: /IVS (for T0)
T5 10 20 Rear mounting: /Z
TM 8 16 Flush mounting main switch EA/SVB
(2)
Surface mounting main switch: I../SVB
Rear mounting main switch: /V/SVB
(2)
Designs for: TM: /E/EZ or /IVS
Contact sequence
The adjacent form makes it easier to specify the contact sequence.
Switching angle
30, 45, 60, 90
o
Preferred angle: 60
o
For On-Off switches: 90
o
For main switches: 90
o
as FS 908
Changeover with interruption between 2 positions (ON-OFF-ON) not
permissible for T0, T3 and TM = 30
o
, 45
o
; for T5 (T5B) = 30
o
Star delta switch only with switching angle ≥ 60
o
Terminal marking
TM switches have consecutive terminal markings starting with 1.
Automatic (spring) return
The switching action is limited by a stop. The switch returns under spring
pressure to the last position. Where a switch has Automatic (spring) return
from both directions, a maximum of max. 3 positions can be traversed.
The Automatic (spring) return angle is ≤½ switching angle. A max of 6
contacts can be returned at the same time.
The switching angle of Automatic (spring) return TM mini rotary switch
must be ≥ 60
o
.
Fleeting contacts
The duration of the fleeting contact depends primarily on the actuation
speed. In order to actuate a contactor with a fleeting pulse, the switching
angle of the cam switch must not be less than 60
o
, since the pulse time can
be too short if the switching angle is smaller. Fleeting contact elements
always cooperate in both operating directions.
Complete rotation
Only possible with a total switching angle at 360
o
the direction of
switching can be either operating direction. The number of switch position
multiplied by the switching angle must be 360
o
, TM with 12 positions (one
every 30
o
) only available with complete rotation, not with stop.
Front plates
Front plates are part of the equipment supplied with a ‘first order of rotary
switch’ and therefore do not need to be ordered separately.
Number of contact units
Number of contact/2 = Round up to nearest whole number
The number chamber = contact unit (BE) has 1 or 2 contacts, each of which
is actuated by a cam.
In T5(B) there is a common cam for both contacts. Because of this, the
following applies for T5(B): If the total switching angle is less than 180
o
,
the contacts can be switched independently of each other. With switching
angles for greater than or equal to 180
o
, there can only be 2 contacts in the
same chamber, if their switching sequences are the same but are offset by
180
o
(e.g. TS5-4-8235 step switch)
Standard features
Same as cam switch with standard contact sequence.
Note: It is possible that the order of the contacts is altered due to technical reasons. For special switches, bridges are only
possible between an even or uneven number. Other connections must be made by the user installation.
(1) For T0-.../I1 max 4 contact units
For T3.../I2 max 5 contact units
(2) For T0 up to a max 8 contact = 4 BE
For T3: up to a max. of 12 contacts = 6 BE
174
EATON P Switch-disconnectors and T Rotary cam switches CA042001EN