SMT Software Engineering Group IM Operations Y AMAHA MOTOR CO., L TD MDOC-SOFT50282 13/17 4.2 Machine Setting It is possible to c h ange the timing to display the notification me ssage on [Machine] – [S peci…

SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD
MDOC-SOFT50282
12/17
Fig 4.2 the [Unit log] screen and [Management of ID log] screen
- When you use maintenance notice based on pickup error rate, it is recommended to set
[Server Path]. By setting [Server Path], individual log file is saved for each Feeder ID, and
the information is taken over at power OFF/ON and shared among other machines.

SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD
MDOC-SOFT50282
13/17
4.2 Machine Setting
It is possible to change the timing to display the notification message on [Machine] –
[Specification Information] - [Maintenance Specification] – [Feeder].
Fig 4.3 the [Machine] – [Specification Setting] - [Maintenance Specification] – [Feeder]
screen
Table 4.1 items on [Machine]–[Specification Information]-[Maintenance
Specification]–[Feeder]
Item Function
Notice timing Timing to display the maintenance notice message or stop
error.
You can take multiple selections. For details of each item,
refer to Table 4.2.
When no item is selected, the message is not displayed.
By default, only “Feeder ON/OFF” is selected.

SMT Software Engineering Group
IM Operations YAMAHA MOTOR CO., LTD
MDOC-SOFT50282
14/17
Item Function
Feeder MACS Correct Feeder maintenance notice according to Feeder MACS
correction value.
OFF … unavailable
ON … available
It is set to “OFF” by default.
Pickup Err Rate Feeder maintenance notice according to pick up error rate.
OFF … unavailable
ON … available
It is set to “OFF” by default.
Min. Sample Cnt This item is available when Pickup Err Rate is ON. Pick up
error rate is calculated based on this count.
Allowable range is 10 to 10000 times.
It is set with “100” by default.
Maintenance Stop If you want to stop the machine when it reaches Stop Count,
select ON.
OFF … unavailable
ON … available
It is set to “OFF” by default.
Notice Cnt
(10,000times)
Stop Cnt
(10,000times)
Feeding count that is allowed before the next maintenance
notice or stop.
You can set different values for SS feeder and ZS feeder
separately, by switching [Feeder Group] to “SS Type” or “ZS
Type”.
A recommended value is set by default (Table 4.3), so that
usually you don’t need to change this value.
Allowable range is 0 to 65535 (10,000times). When “0” is set,
the maintenance notice and stop for the feeder is not
displayed.