TS5624DMP-User-Guide.pdf - 第12页

12 12. LIMITED WARRANTY Manufacturer warrants this product to the original purchaser for a period of one (1) year from date of pu rchase to be free fro m defects in material and workmanship, but not against damages by mi…

100%1 / 12
10
10. ACCESSORIES
10.1 FLUID FITTINGS AND TUBING
10.2 BRACKETS
PART NUMBER
DESCRIPTION
TS918-46
4-Way Fluid Manifold
TN00DKIT
Complete Dispensing Tip Kit
9000-000-100
Sample Tip Kit
PART NUMBER
DESCRIPTION
TSD1003-16
⅛'' NPT to ¼'' O.D. Tube, 90° Elbow
TSD1002-17
⅛'' NPT to ⅜'' O.D. Tube
TSD1002-18
⅛'' NPT to ¼'' O.D. Tube
TSD1002-38
¼'' NPT to ¼'' O.D. Tube
TSD1099-22
⅜'' O.D. X ¼'' I.D. Tube, Black, Polyethylene
TSD1099-23
⅜'' O.D. X ¼'' I.D. Tube, Clear, Polyethylene
TSD1099-24
¼'' O.D. X ⅛'' I.D. Tube, Clear, Polyethylene
TSD1099-25
¼'' O.D. X ⅛'' I.D. Tube, Black, Polyethylene
TSD1099-45
6mm O.D. X 4mm I.D, Clear, Polyethylene
TSD1099-46
6mm O.D. X 4mm I.D, Black, Polyethylene
TSD126-360BPK
Luer Lock Tubing, 60'' (1524mm) , Black
PART NUMBER
DESCRIPTION
918-033-000
Productions Master Stand (Base & Support)
918-000-012
Rod Clamp Assembly
5620-000-008
4'' (101.6mm) Threaded Mounting Rod
7509-9100
Syringe Bracket With Inserts
11
11. TROUBLE SHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTION
No fluid flow
Fluid pressure too low
Increase fluid pressure
Operating pressure too low
Increase air pressure to 70 psi
(4.8bar)
Dispense tip clogged
Replace tip
Fluid cured in valve chamber
Replace material path
Stroke adjustment closed
Open stroke adjustment
counterclockwise
Inconsistent
fluid flow
Fluid pressure fluctuating
Ensure fluid pressure is
constant
Valve operating pressure is too
low
Increase valve pressure to 70
psi (4.8bar)
Valve open time is not
consistent
Check to make sure the valve
controller is providing a
consistent output
Air trapped in fluid housing
Purge valve
Fluid drools after
the valve closes,
eventually
stopping
Air trapped in fluid chamber
Purge valve
Steady drip
Worn material path
Replace material path
Fluid pressure exceeds 60 psi
(4.1bar)
Lower fluid pressure
12
12. LIMITED WARRANTY
Manufacturer warrants this product to the original purchaser for a period of one (1)
year from date of purchase to be free from defects in material and workmanship,
but not against damages by misuse, negligence, accident, faulty installations and
instructions. Manufacturer will repair or replace (at factory’s option), free of
charge, any component of the equipment thus found to be defective, on return of
the component, “PREPAID” to the factory during the warranty period. In no event
shall any liability or obligation of the Manufacturer arising from this warranty
exceed the purchase price of the equipment. This warranty is only valid if the
defective product is returned as a complete assembly without physical damage.
The Manufacturer’s liability, as stated herein, cannot be altered or enlarged except
by a written statement signed by an officer of the company. In no event shall the
Manufacturer be liable for consequential or incidental damages. A return
authorization is required from Techcon Systems prior to shipping a defective unit
to the factory.
Manufacturer reserves the right to make engineering product modifications
without notice.
All returns must be issued with a Returns Authorization number, prior to return.
Send warranty returns to:
Americas and Asia
OK International
Garden Grove Division
12151 Monarch Street
Garden Grove, Ca 92841
Europe
OK International
Eagle Close
Chandler’s Ford Ind Est
Eastleigh
Hampshire
SO53 4NF
United Kingdom
www.techconsystems.com
7000-4760_A