2 Retrofit Instructions for PCB Camera Multicolor, HS-50 / HS-60 SIPLACE HS- 50/HS-60 2.9 SITEST: Configuration and Illumination Check of all PCB Cameras Multicolor 11/2004 Edition 70 2 : In the SIT EST prog ram 502.xx s…

SIPLACE HS-50/HS-60 2 Retrofit Instructions for PCB Camera Multicolor, HS-50 / HS-60
11/2004 Edition 2.9 SITEST: Configuration and Illumination Check of all PCB Cameras Multicolor
69
: In the configuration menu of gantry 1, mark the option "Multicolor" and select "Accept" (button).
: One after the other, select the remaining gantries 2, 3 and 4 as described above.
: Conduct the illumination check for the PCB cameras Multicolor as described below in Abschn.
2.10.2.
: Exit the menu "Machine configuration" by pressing "Accept".
: Restart the machine so that the configuration will be accepted.
: Return to the SITEST.
: In the main view, press the button "Total reference run".
: Afterwards do the calibration.
Calibrate all placement heads and cameras.
2.9.1 Illumination Check
NOTE:
We recommend you the illumination check after installation of the PCB camera Multicolor. By ap-
propriately switching over the vision screen (see User Manual) it is possible to precisely check the
function of the pertinent light level and, for example, the change from full to one-half brightness.2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

2 Retrofit Instructions for PCB Camera Multicolor, HS-50 / HS-60 SIPLACE HS-50/HS-60
2.9 SITEST: Configuration and Illumination Check of all PCB Cameras Multicolor 11/2004 Edition
70
2
: In the SITEST program 502.xx select the ICON "Gantries" and then the "Gantry 1" .
: Click on the CON "PCB camera functions" .
The following screen is displayed (using S-25 HM as an example):
Fig. 2.91.2 Menu "Setting of Illumination" for PCB Camera"
2
: Click on the button "Illumination values for live image".
In principle, you can use this function to test whether the illumination of the PCB camera Mul-
ticolor is activated. The illumination levels "White" and "Blue" are visible; "IR" is not.
2
2
2
2
2
2

SIPLACE HS-50/HS-60 2 Retrofit Instructions for PCB Camera Multicolor, HS-50 / HS-60
11/2004 Edition 2.9 SITEST: Configuration and Illumination Check of all PCB Cameras Multicolor
71
: The screen "Illumination values for live image" is displayed (using S-25 HM as an example):
Fig. 2.91.3 Screen: "Illumination Values for Live Image"
: Test at least the illumination levels "White" and "Blue" because their light is visible.
: Click on the "Radio button" to select the illumination level "White".
: Deactivate the button "Reduced brightness" and click on the button "Accept".
The complete illumination level is therefore activated at the outset.
: Switch to the menu "Teach PCB camera" -> Click on the button "PCB camera":
Make a visual check (with safety hoods closed):
The camera’s white light must flash.
: Once again, press the button "Illumination values for live image".
: Now activate the option "Reduce illumination".
This reduces the illumination level by one-half.
: Click on the button "Accept" again.
: Make a visual check (with the safety hoods closed):
The camera’s white light must flash repeatedly but not as brightly as before.
: Execute the above-described check for illumination level "blue" as well.