Error Code List.pdf - 第25页
RL1 31 ERROR CODE LIST 2.4 Errors DA8EEC- 91-210- A0 2.4- 2 34 Counter e rror DESCRI PTIO N Counter e rror of ax i s con troller CAUSE Trouble of ax i s con t rolle r board in CPU box SOLU TION Ne c essary t o e xchange …

RL131
ERROR CODE LIST
2.4 Errors
DA8EEC-91-210-A0
2.4-1
2.4. Errors
DA8EEC-91-210-A0
7
Emergency switch ON
DESCRIPTION
Emergency switch was detected.
CAUSE
An emergency stop switch was pressed.
SOLUTION
Release the emergency stop switch. (There are five switches. Front; 2 Rear; 3) If the same message appears after
releasing the switch, the switch may be broken. Confirm emergency SW signal in the [Input check] of [Machine
adjustment].
NOTE
8
Servo switch OFF
DESCRIPTION
Servo switch off
CAUSE
A servo switch is pressed.
SOLUTION
Release the servo switch (1 in front and 1 in back). (KEYLOCK LED of operation panel turns OFF.)
If the same message appears after releasing the switch, the switch may be broken.
NOTE
9
Air pressure drop
DESCRIPTION
Air pressure drop
CAUSE
Air pressure has dropped.
SOLUTION
When supplied air pressure has dropped, supply air at 0.49MPa - 0.78MPa.
Excessively high setting of the air pressure detector causes an error. Set to 0.4MPa.
Confirm Air pressure (5800H:bit2) in the [input check menu] of [machine adjustment]. ON: OK, OFF: Drop
NOTE
12
Cover open stop
DESCRIPTION
Door or cover is open
CAUSE
Safety cover is left open.
SOLUTION
Close the door or cover, then push [return].
Confirm Cover switch (5800H:bit3, 4, 5) in the [input check menu] of [machine adjustment]. ON: Close, OFF: Open
NOTE
17
PCB transport error
DESCRIPTION
PCB remains at the transferring part, or PCB is broken.
CAUSE
PCB cannot be transferred properly.
SOLUTION
Check the PCB transfer unit for proper operation.
NOTE

RL131
ERROR CODE LIST
2.4 Errors
DA8EEC-91-210-A0
2.4-2
34
Counter error
DESCRIPTION
Counter error of axis controller
CAUSE
Trouble of axis controller board in CPU box
SOLUTION
Necessary to exchange axis controller board.
Please inform us the axis name and the situation.
NOTE
35
Returning to origin error
DESCRIPTION
Incomplete returning to origin
CAUSE
Axis can't move smoothly.
Motor driver trouble
Trouble of axis controller board in CPU box
Getting loose of motor coupling
Disconnection of motor wiring
Trouble of axis I/O sensor
SOLUTION
Inspection of axis. (Dust etc.)
Exchange motor driver.
Exchange axis controller board.
Confirm I/O sensor status in the [Input check menu] of [Machine adjustment]. Check 1260H, 1261H, 1262H, 1263H,
9806H, 9816H, 9826H, A006H, A016H, A026H, A806H, A816H, A826H, A836H, B006H, B016H, B026H, B036H.
Please inform us the axis name and the situation.
NOTE
37
Data error (Soft limit)
DESCRIPTION
Move data beyond limit is sent to axis controller.
CAUSE
Move data beyond limit exists in pickup position data and mount data.
SOLUTION
Check pickup position data and mount data.
Please inform us the axis name and the situation.
NOTE
38
(+) Overrun
DESCRIPTION
Axis (+) overrun sensor is ON.
CAUSE
Trouble of sensor
SOLUTION
Execute return to origin in the [Ret orig] of [Machine adjustment].
[Confirm I/O sensor status in the [Input check menu] of [Machine adjustment].
Confirm setting of CPU box board (MCMJEX) and connection of connector.
Please inform us the axis name and the situation.
NOTE

RL131
ERROR CODE LIST
2.4 Errors
DA8EEC-91-210-A0
2.4-3
39
(-) Overrun
DESCRIPTION
Axis (-) overrun sensor is ON.
CAUSE
Trouble of sensor
SOLUTION
Execute return to origin in the [Ret orig] of [Machine adjustment].
Confirm I/O sensor status in the [Input check menu] of [Machine adjustment].
Confirm setting of CPU box board (MCMJEX) and connection of connector.
Please inform us the axis name and the situation.
NOTE
40
Driver error
DESCRIPTION
A motor driver error was detected
CAUSE
The motor drive detected an error.
SOLUTION
Confirm error code of 7 segment LED of error occurred axis driver.
Power OFF and ON, leave 5 minutes in main menu then restart.
Please inform us the axis name^ error code of 7 segment LED and the situation.
NOTE
47
Interlock error
DESCRIPTION
Unregistered interlock error occurred.
CAUSE
NC board detected an error of an unregistered axis number.
SOLUTION
Please inform us the axis name and the situation.
If restart is impossible, once power OFF/ON.
NOTE
49
Axis controller communication error
DESCRIPTION
No response from axis controller.
CAUSE
No response against command to axis controller.
SOLUTION
Please inform us the axis name and the situation.
NOTE
51
Conveyor width adjust error
DESCRIPTION
Unable to width adjust because PCB exist on the conveyor.
CAUSE
Width cannot be adjusted when there is a PCB on the conveyor because it may drop or get caught.
SOLUTION
Remove PCB.
NOTE
53
Power box over heat
DESCRIPTION
Temperature in power box is high.
CAUSE
Temperature in power box is over the reference value.
SOLUTION
Check fan moving.
NOTE