Error Code List.pdf - 第62页
RL1 31 ERROR CODE LIST 2.4 Errors DA8EEC- 91-210- A0 2.4- 39 2733 PCB sw ee p out re start cance l DESCRI PTIO N Re start of PCB swe ep -out was cance led. CAUSE Conditions r equi red for r esta r ting PC B swe ep-out m …

RL131
ERROR CODE LIST
2.4 Errors
DA8EEC-91-210-A0
2.4-38
2712
An error occurred during origin returning for any of C, X, Y, θH, θA or P. Origin return of all axes
canceled.
DESCRIPTION
Origin return was not completed.
CAUSE
Any of axes (C, X, Y, θH, θA or P) is abnormal.
SOLUTION
Please confirm each axis condition and then return all axes to their origins again.
NOTE
2713
The θH axis is not at its origin. Origin return of all axes canceled.
DESCRIPTION
Origin return was not completed.
CAUSE
The θH axis is not at its origin.
SOLUTION
Move the θH to its origin and then return all axes to their origins again.
NOTE
2714
The θU axis is not at the waiting position. Origin return of all axes canceled.
DESCRIPTION
Origin return was not completed.
CAUSE
The θU axis is not at the waiting position.
SOLUTION
Move the θU axis to the waiting position and then return all axes to their origins again.
NOTE
2715
An error occurred during origin returning for the θU axis. Origin return of all axes canceled.
DESCRIPTION
Origin return was not completed.
CAUSE
An error for the θU axis was detected during origin returning.
SOLUTION
Pleasse confirm the origin return conditions for the θU axis and then return all axes to their origins.
NOTE
2731
PCB carry in restart cancel
DESCRIPTION
Restart of PCB carry-in was canceled.
CAUSE
Conditions required for restarting PCB carry-in may have not been satisfied.
SOLUTION
Check the conditions for restarting PCB carry-in.
NOTE
2732
PCB carry out restart cancel
DESCRIPTION
Restart of PCB carry-out was canceled.
CAUSE
Conditions required for restarting PCB carry-out may have not been satisfied.
SOLUTION
Check the conditions for restarting PCB carry-out.
NOTE

RL131
ERROR CODE LIST
2.4 Errors
DA8EEC-91-210-A0
2.4-39
2733
PCB sweep out restart cancel
DESCRIPTION
Restart of PCB sweep-out was canceled.
CAUSE
Conditions required for restarting PCB sweep-out may have not been satisfied.
SOLUTION
Check the conditions for restarting PCB sweep-out.
NOTE
2734
PCB carry start conditional not satisfies
DESCRIPTION
Failed to start PCB carry.
CAUSE
Lack of conditions required for starting PCB carry
SOLUTION
Check the conditions for starting PCB carry.
NOTE
2735
Rail down condition not satisfies
DESCRIPTION
The rail failed to be moved down.
CAUSE
Lack of conditions required for moving down the rail.
SOLUTION
Check the conditions for moving down the rail.
NOTE
2736
Arm carry condition not satisfies
DESCRIPTION
The transfer arm failed to move.
CAUSE
Lack of conditions required for moving the transfer arm.
SOLUTION
Check the conditions for moving the transfer arm.
NOTE
2737
Arm slowdown condition not satisfies
DESCRIPTION
The transfer arm failed to slow down.
CAUSE
Lack of conditions required for slowing down the transfer arm.
SOLUTION
Check the conditions for slowing down the transfer arm.
NOTE
2738
Rail up condition not satisfies
DESCRIPTION
The rail failed to be moved up.
CAUSE
Lack of conditions required for moving up the rail.
SOLUTION
Check the conditions for moving up the rail.
NOTE

RL131
ERROR CODE LIST
2.4 Errors
DA8EEC-91-210-A0
2.4-40
2739
Arm return condition not satisfies
DESCRIPTION
The transfer arm failed to return.
CAUSE
Lack of conditions required for returning the transfer arm
SOLUTION
Check the conditions for returning the transfer arm.
NOTE
2748
Emergency stop switch ON safety stop
DESCRIPTION
Emergency switch was detected.
CAUSE
An emergency stop switch was pressed.
SOLUTION
Release the emergency stop switch. (There are five switches. Front; 2 Rear; 3) If the same message appears after
releasing the switch, the switch may be broken. Confirm emergency SW signal in the [Input check] of [Machine
adjustment].
NOTE
2756
Axis related error
DESCRIPTION
Axis fault detected.
CAUSE
An axis error has occurred; however its factors cannot be determined.
SOLUTION
Check the conditions of the time when the error occurred and the details of the error, and then contact us.
NOTE
2757
PCB recognition error (23)
DESCRIPTION
PCB recognition error was detected.
CAUSE
Invalid recognition parameter
SOLUTION
Check for any abnormality in the recognition parameter.
NOTE
2758
PCB recognition error (16)
DESCRIPTION
PCB recognition error was detected.
CAUSE
Outline detection error occurred with the recognition hole.
SOLUTION
Check the condition of the PCB hole.
NOTE
2759
PCB recognition error (17)
DESCRIPTION
PCB recognition error was detected.
CAUSE
Improper hole search area
SOLUTION
Check the value of the search area size in the recognition initial setting. Check the condition of the target hole.
NOTE