Error Code List.pdf - 第53页

RL1 31 ERROR CODE LIST 2.4 Errors DA8EEC- 91-210- A0 2.4- 30 2451 Right rail belt mot or tim eou t DESCRI PTIO N Belt motor was stoppe d due to tim eo ut o f the right rail be l t mo t or. CAUSE PC B f ai l ed t o r ea c…

100%1 / 74
RL131
ERROR CODE LIST
2.4 Errors
DA8EEC-91-210-A0
2.4-29
2382
Rail up condition not satisfies (XY movement)
DESCRIPTION
Rail up action was not done because of the lack of the rail up condition.
CAUSE
X or Y axis is moving.
SOLUTION
It is necessary to have stopped X and Y axis to up rail.
NOTE
2409
Arm return condition not satisfies (left rail return limit)
DESCRIPTION
Arm return action was not done because of the lack of the return condition.
CAUSE
Left rail return limit has been turned off.
SOLUTION
It is necessary to have turned on the left rail return limit to return arm.
NOTE
2416
Arm return condition not satisfies (positioner return limit)
DESCRIPTION
Arm return action was not done because of the lack of the return condition.
CAUSE
Positioner lever return limit has been turned off.
SOLUTION
It is necessary to have turned on the positioner lever return limit to return arm.
NOTE
2421
Arm return condition not satisfies (right rail return limit)
DESCRIPTION
Arm return action was not done because of the lack of the return condition.
CAUSE
Right rail return limit has been turned off.
SOLUTION
It is necessary to have turned on the right rail return limit to return arm.
NOTE
2424
Arm return condition not satisfies (transfer arm traverse limit)
DESCRIPTION
Arm return action was not done because of the lack of the return condition.
CAUSE
Transfer arm traverse limit has been turned off.
SOLUTION
It is necessary to have turned on the transfer arm traverse limit to return arm.
NOTE
RL131
ERROR CODE LIST
2.4 Errors
DA8EEC-91-210-A0
2.4-30
2451
Right rail belt motor timeout
DESCRIPTION
Belt motor was stopped due to timeout of the right rail belt motor.
CAUSE
PCB failed to reach the right rail outlet sensor within the prescribed time after the right rail started rotating.
(1) Misdetection by the outlet sensor
(2) Dropped PCB during transport
(3) PCB jam during transport
(4) PCB was removed during transport.
(5) Belt motor started rotating due to false detection by the inlet sensor.
SOLUTION
Check the outlet sensor.
Adjust the rail width.
Load a PCB again.
Check the inlet sensor.
NOTE
2452
Left rail belt motor timeout
DESCRIPTION
Belt motor was stopped due to timeout of the left rail belt motor.
CAUSE
PCB failed to reach the left rail outlet sensor within the prescribed time after the left rail started rotating.
(1) Misdetection by the outlet sensor
(2) Dropped PCB during transport
(3) PCB jam during transport
(4) PCB was removed during transport.
(5) Belt motor started rotating due to false detection by the inlet sensor.
SOLUTION
Check the outlet sensor.
Adjust the rail width.
Load a PCB again.
Check the inlet sensor.
NOTE
2453
Right rail down movement timeout
DESCRIPTION
Timeout was detected during lowering process of the right rail.
CAUSE
Right rail lower limit sensor failed to turn ON within the prescribed time after the right rail started lowering.
(1) Misdetection by the lower limit sensor
(2) Malfunction of the cylinder
SOLUTION
Check the lower limit sensor.
Check the cylinder for proper operation.
NOTE
2454
Right rail up movement timeout
DESCRIPTION
Timeout was detected during rising process of the right rail.
CAUSE
Right rail upper limit sensor failed to turn ON within the prescribed time after the right rail started rising.
(1) Misdetection by the upper limit sensor
(2) Malfunction of the cylinder
SOLUTION
Check the upper limit sensor.
Check the cylinder for proper operation.
NOTE
RL131
ERROR CODE LIST
2.4 Errors
DA8EEC-91-210-A0
2.4-31
2455
Left rail down movement timeout
DESCRIPTION
Timeout was detected during lowering process of the left rail.
CAUSE
Left rail lower limit sensor failed to turn ON within the prescribed time after the left rail started lowering.
(1) Misdetection by the lower limit sensor
(2) Malfunction of the cylinder
SOLUTION
Check the lower limit sensor.
Check the cylinder for proper operation.
NOTE
2456
Left rail up movement timeout
DESCRIPTION
Timeout was detected during rising process of the left rail.
CAUSE
Left rail upper limit sensor failed to turn ON within the prescribed time after the left rail started rising.
(1) Misdetection by the upper limit sensor
(2) Malfunction of the cylinder
SOLUTION
Check the upper limit sensor.
Check the cylinder for proper operation.
NOTE
2457
Transfer arm forward movement timeout
DESCRIPTION
Timeout was detected during forward process of the transfer arm.
CAUSE
Transfer arm forward limit sensor failed to turn ON within the prescribed time after the transfer arm started moving.
(1) Misdetection by the forward limit sensor.
(2) Malfunction of the transfer arm
(3) Faulty inverter unit
SOLUTION
Check the forward limit sensor.
Check the transfer arm for proper operation.
Check the inverter unit.
NOTE
2458
Transfer arm return movement timeout
DESCRIPTION
Timeout was detected during return process of the transfer arm.
CAUSE
Transfer arm return limit sensor failed to turn ON within the prescribed time after the transfer arm started moving.
(1) Misdetection by the return limit sensor
(2) Malfunction of the transfer arm
(3) Faulty inverter unit
SOLUTION
Check the return limit sensor.
Check the transfer arm for proper operation.
Check the inverter unit.
NOTE