YSM20_YSM20W_Mainte_E.pdf - 第170页

6-17 6 How to replace consumable parts n NOTE The tension measurement positions of this machine and the tension standards are as below. Adjust with tension meter as needed. Conveyor belt: T ension measurement locations a…

100%1 / 179
6-16
6
How to replace consumable parts
q
Clean the belt guides and pulleys.
1. Use a vacuum assembly (option) to suck
the belt wear debris on the belt guides
and sensors, etc.
2. Use a plastic spatula or similar tool to
remove the belt wear debris adhering to
the outer peripheral surface of the
pulleys.
3. Use a brush or similar tool to remove the
belt wear debris caught in the belt
guides.
c
CAUTION
Use a plastic spatula and brush to avoid scratching the
pulleys and guides.
c
CAUTION
Do not use a solvent (IPA, etc.) unless the guides and
pulleys are excessively dirty. If using a solvent, be
careful not to spill the solvent on the bearing in the
pulleys during cleaning.
w
Replace the conveyor belt.
1. Reattach a new belt temporarily while
putting it on the pulley.
2. (Dual-stage: W2, W3) Pass the drive
pulley through the shaft.
3. Loosen the mounting bolt and connect
the shaft.
4. Move the bracket (YSM20W Single-lane:
pulley) to the position marked in Step 4
and install the mounting bolts.
5.
If looseness of the belt is found, adjust the
bracket (pulley) position to apply tension.
c
CAUTION
The followings are tightening torques of the tensioner
mounting bolts. Do not tighten the bolt excessively.
Pulley bracket mounting bolt : 3.8 N•m.
Pulley mounting bolt : 5.5 N•m.
Cleaning the belt guide and pulley
Step 11
Spatula
(made of plastic)
Belt guide
Belt wear debris
sticking to pulley
Brush
Outer peripheral
surface of pulley
Belt guide
Outer peripheral
surface of pulley
53620-N2-10
6-17
6
How to replace consumable parts
n
NOTE
The tension measurement positions of this machine and the tension standards are as below.
Adjust with tension meter as needed.
Conveyor belt: Tension measurement locations and tension standards
YSM20
Transfer
direction
Dual-stage type
STD: 425 - 475 Hz
EXT: 100 - 120 Hz
Single-lane type
STD: 490 - 540 Hz
STD: 490 - 540 Hz
STD: 425 - 475 Hz
EXT: 100 - 120 Hz
STD: 420 - 460 Hz
EXT: 420 - 460 Hz
W1
W2W3
W4
Transfer
direction
Tension measurement location:
STD: Tension of standard conveyor
EXT: Tension of extended conveyor
53632-N2-00
6-18
6
How to replace consumable parts
Transfer direction
Dual-lane type
Lane 1
Lane 2
STD: 420- 460 Hz
EXT: 420 - 460 Hz
Single-lane type (transferring heavy boards)
STD: 420- 460 Hz
EXT: 420 - 460 Hz
STD: 274-334 Hz STD: 274-334 Hz
Transfer direction
Transfer direction
Conveyor belt: Tension measurement locations and tension standards
YSM20W
Tension measurement location:
STD: Tension of standard conveyor
EXT: Tension of extended conveyor
53633-N2-00