Nordson-EFD-PM100-Operating-Manual.pdf - 第18页
ProcessMate 100 Vacuum Pick-Up System 18 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide. 1 2 3 4 5 6 7 8 9 10 11 Replacement Parts Item …

17www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
ProcessMate 100 Vacuum Pick-Up System
Vacuum Pickup Pen
Part # Description
7016107 Vacuum pickup pen (complete)
Vacuum Straight Tips (does not include vacuum cups)
Part # Size Description Quantity
7018043 14 gauge Tips (olive) 50/box
7018233 21 gauge Tips (purple) 50/box
Vacuum Pickup Tips, 45º Angled (does not include vacuum cups)
Part # Size Description Quantity
7016906 14 gauge Tips (olive) 50/box
7016908 18 gauge Tips (green) 50/box
7016910 21 gauge Tips (purple) 50/box
Vacuum Cups
Part # Size Description Quantity
7016889 0.0938" diameter Vacuum cups 10/box
7016883 0.1250" diameter Vacuum cups 10/box
7016887 0.1875" diameter Vacuum cups 10/box
7016881 0.2500" diameter Vacuum cups 10/box
7016891 0.3750" diameter Vacuum cups 10/box
Accessories (continued)

ProcessMate 100 Vacuum Pick-Up System
18 www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
1
2
3
4
5
6
7
8
9
10
11
Replacement Parts
Item Part # Description
1 7012274 Regulator knob, black
2 — Regulator bezel
3 7012277 Regulator assembly, 0–100 psi
4 7014752 Regulator replacement O-rings
5 — On / off rocker switch assembly
6 — Overlay, front, PM100
7 — Panel, rear, PM100
8 7022009 Case, pack of 2 (top / bottom)
9 7015199 Universal power supply, power supply plug kit
10 7014865 Foot pedal assembly
11 — Muffler, 6 mm push-in
9

19www.nordsonefd.com info@nordsonefd.com +1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
ProcessMate 100 Vacuum Pick-Up System
Troubleshooting
Problem Solution
No power Check the power supply connection and DC power supply to the unit.
No vacuum Check the main air supply and primary regulator.
Check to make sure that the main air supply is connected to the back of the unit and has not
come loose.
Check to make sure that the regulator is not turned off (fully counterclockwise).
Check the vacuum pickup pen wand assembly for possible contamination or clogs.
Check that the vacuum exhaust is not blocked or covered.
For heavier and larger items, use larger tips and cups and increase vacuum.