7. SOFTWARE UPGRADE
Note: For future software upgrade, follow the instructions below.
1. Download the latest software version from Techcon website and copy it to
a blank USB thumb drive. Note: Do not put the software file inside a
folder
2. Make sure that the unit is turned off
3. Insert the USB drive to the USB port located in the back of the unit
4. Turn on the unit
5. Wait while the system is loading the new software. This process can take
a few minutes
6. Wait until the system completes the software update from the USB drive
and the first touch-screen calibration is displayed
7. Remove the USB drive from the USB port before proceeding to the next
step
8. Follow the instructions on the display to calibrate the touch screen by
touching the crosshair at five different points. Note: In order to
accurately calibrate the touch screen, it’s recommended that the stylus
pen is used

26
9. Wait until the system completes the rebooting sequence and the home
screen is displayed
10. Repeat sections 5.1.1 and 5.1.2 to re-calibrate the air pressure

27
8. TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
CORRECTION
Display does
not light up
• No power inputs
• Check power cord
connections
• Turn on power
System will not
actuate
• Supplied pressure
dropped below “Low
Pressure” setting
• Foot switch not plugged
in or improperly
plugged in
• Defective foot switch
• Broken wire or loose
connection inside unit
• Defective solenoid
• Defective PC board
• Increase supplied
pressure
• Check foot switch
connection
• Foot switch needs to be
repaired or replaced
• Unplug power cord and
disconnect air supply.
Remove cover and check
for broken wires or loose
connections
• Replace solenoid
• Replace PC board
System will not
pressurize
• Insufficient air pressure
• Air hoses not plugged
in
• Regulator defective
• Increase air supply
pressure
• Check connection
• Replace regulator
Inconsistent
dispense
• Air bubbles in material
• Dispense time is too
low
• Needle clogged
• De-air material
• Increase dispense time
• Replace needle