TS555R-UserGuide.pdf - 第5页
5 3. SPECIFICA TIONS 4. FE ATURES Figure 1.0 Size 290mm x 212mm x 98 mm (11.4” X 8.3” X 3.9”) Weight 2.9 kg (6.4lbs) Input Voltage 24VDC Output Voltage Range 0-24 VDC Rated Power 15W Air Input 100 psi (6.9 bars) Max. Air…

4
2. SYMBOL DEFINITIONS
Symbol
Description
Symbol
Description
Run (Activate)
Setup
Pressure Port A
Counter reset
Pressure Port B
Mac address
Timed mode
Accept change
Interrupt mode
Pressure calibration
Teach mode
Save
Purge mode
Reset time in Teach
mode
Dispense
IP address
Login/Logout
Cancel
Run Method
Sequence Mode
Continuous Mode
Sequence
Continuous Mode
E-Stop
Change Password
Remote Server
On line
Off Line
Stand Alone Control
Mode
Robotic Mode
Max Input Pressure
Setting

5
3. SPECIFICATIONS
4. FEATURES
Figure 1.0
Size
290mm x 212mm x 98mm
(11.4” X 8.3” X 3.9”)
Weight
2.9 kg (6.4lbs)
Input Voltage
24VDC
Output Voltage Range
0-24 VDC
Rated Power
15W
Air Input
100 psi (6.9 bars) Max.
Air Output
0-99.9 Psi (6.9 bar)
Pollution Degree
II
Installation Category
I
Indoor Use
Altitude up to 2,000m (6,562ft)
Operating Temperature
0˚C to 50˚C (32˚F to 122˚F)
Storage Temperature
-10˚C to 60˚C (14˚F to 140˚F)
Max. Relative Humidity
80% for temperature up to 31˚C (87.8˚F) Decreasing
linearly to 50% relative humidity at 40˚C (104˚F)
Timer
0.008-99.99 seconds
Cycle Mode
Timed, Interrupt, Teach, Purge
Timing Repeat Tolerance
+/- 0.001%
Cycle Rate
900 cycles/min
Display
Touch Screen, Resistive
Meets or exceed
CE, TUV and NRTL

6
5. TO CONTROL PNEUMATIC VALVE
CAUTION: A 5-micron filter (TSD800-6) must be installed with the unit to ensure proper
air filtration.
Figure 2.0
5.1 Connecting the Unit: (Refer to Figure 1.0 and 2.0)
1. Connect the power cord, foot switch to the back of the unit.
2. Connect Valve air hose Port A
3. Connect the Fluid pressure hose to Port B
4. Press the Power switch to turn on the unit.
Items
Description
1
Air Filter
2
Valve (not included)
3
Pressure Pot (not included)
4
Display
5
Power Adapter
6
Foot Switch