8 Repairs to SmartFeeder 2x8 mm X / Xi 8.16 Handle with control panel Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 235 8.16.1 Removing the handle assembly ► Remove the le…

100%1 / 246
8 Repairs to SmartFeeder 2x8 mm X / Xi
8.16 Handle with control panel
234 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
8.16 Handle with control panel
Spare part required
NOTICE
New spare part
Spare part "Handle X2x8" [03072432Sxx] is no longer available.
This item can only be replaced as a complete unit.
The new "Handle X2x8 assy. [03170776-xx] is available as a compatible replacement.
It is now possible to replace individual parts of this handle.
Fig.77: Handle X2x8 assy.
Feeder module Item no. Designation
SmartFeeder 2x8mmX 03170776-xx Handle X2x8 assy. (prefitted with flat ribbon cable)
SmartFeeder 2x8 mm Xi 03172629-xx Handle X2x8i assy. (prefitted with flat ribbon cable)
Tools required
●
Phillips screwdriver 0.6Nm
●
TORX screwdriver size T8, 0.6Nm
●
Tweezers
8 Repairs to SmartFeeder 2x8 mm X / Xi
8.16 Handle with control panel
Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020 235
8.16.1 Removing the handle assembly
► Remove the left and right side cover (see 8.3.1
"Removing the Left Side Cover" [}174] and 8.3.3
"Removing the Right Side Cover" [}175]).
► Remove the cover on the foil container.
Carefully place the feeder module on its right side.
► Remove the two pressure springs from the rock-
ers.
► Open the bar on the flat ribbon connection on the
control board.(1)
► Unplug the flat ribbon cable form the connection.
► Carefully pull the flat ribbon cable completely out
through the feedthrough on the tape duct.(2)
► Carefully pull the flat ribbon cable off the adhes-
ive points.
► Remove the two screws marked in the diagram,
which are fastening the handle.
► Stand the feeder module up.
► Open the foil disposal flap.
► Push the handle up to the right-hand side and out
of the feeder module base.
► Close the foil container flap.
8 Repairs to SmartFeeder 2x8 mm X / Xi
8.16 Handle with control panel
236 Service Manual SIPLACE SmartFeeder 4 - 8 mm X / Xi SIPLACE SmartFeeder 2 x 8 mm X / Xi 11/2020
8.16.2 Fitting the handle assembly
► Stand the feeder module up.
► Open the foil disposal flap.
► Push the handle from the right-hand side, as far
as the stop in the feeder module frame.
► Close the foil container flap.
► Place the feeder module carefully down on its
right side
► Fasten the handle using the two marked (see dia-
gram) screws with 0.6Nm.
► Fold the flat ribbon cable in exactly the same way
as the old cable.
► Run the cable and press it into the cable duct and
onto the double-sided adhesive tape. Replace
the adhesive tape if required.
► Carefully insert the flat ribbon cable completely
through the feedthrough on the tape duct.(1)
When running the cable, make sure that the blue
side points upwards at the end of the cable.
► Insert the end of the flat ribbon cable (with the
blue side pointing upwards) as far as the stop in
the marked flat ribbon connection on the control
board.(2)
► Close the connection and make sure that the
cable it firmly fitted.
► Fit the two pressure springs into the rockers.
► Fasten the cover on the foil container.
► Fasten the left and the right side covers (see
8.3.2
"Fitting the Left Side Cover" [}175] and
8.3.4
"Fitting the Right Side Cover" [}176]).