00196798-06_VD_SIPLACE_Explorer2.11_DE_EN.pdf - 第23页
SIPLACE Explorer 2.11 Ausgabe 10/2013 Edition 5 Installation For detailed information ab out the installation and conf iguration proce ss, refer to the document "SIPLACE Explorer 2.11 Installation and Configurat ion…
SIPLACE Explorer 2.11 Ausgabe 10/2013 Edition
●
The following restriction applies to platform I (S20, S23, F4, F5, F5HM) stations with dual conveyors:
The page Production Summary will display Unknown in the Current Recipe List table for the 2nd
conveyor lane.
Reason:
Platform I stations are unable to produce different recipes, even with dual conveyors. Therefore, only
one recipe will be loaded for the SIPLACE production line. This recipe will then only be assigned to
conveyor lane I by SIPLACE Explorer.
● When using the conveyor type "dual conveyor", the board counting function is subject to limitations. It
only records boards for conveyor lane 1. Boards produced on conveyor lane 2 are not recorded.
SIPLACE Explorer and OIS only show the boards for conveyor lane 1.
The components placed on the boards on conveyor lane 2 are assigned to the boards recorded for
lane 1. This means that the number of consumed components shown is correct.
This restriction applies to the following software versions: 407, 408, 502, 503, 504, 505.01, 505.02.
The restriction ceases to apply for version 505.03 onwards.
● If partially placed boards are removed from the SIPLACE machine, without specifying this termination
in the station software and removing them via the output conveyor, these boards will not be recorded
by the OIS and SIPLACE Explorer systems. In this case, the station software is not able to generate
the data set needed to record the boards. This restriction applies to all available versions of the
station software.
If you need to terminate board placement, always proceed as follows:
● Terminate the board at the station software interface.
● Remove the board from the output conveyor of the station and not by opening the hood and
taking it directly out of the placement area.
● The following restrictions apply to the SMA pages listed below, if no boards are placed at the last
station in the production line:
● Machine Navigator:
OLE value will not be shown (N/A).
● OLE / OEE Overview:
Overall Line Efficiency diagram: Values for OLE, performance and availability will not be shown
correctly.
Overall Equipment Efficiency by station diagram: station data is not shown correctly for
stations which do not place boards.
● OEE Analysis:
Table: Values for performance and availability will not be shown correctly for production lines and
stations which do not place boards.
Overall Equipment Efficiency diagram – comparison diagram: Values for OEE, performance
and availability will not be shown correctly for the production line.
● When using MS Windows 2003 Server, the Webhost (Tomcat) must be configured accordingly. For
further details about the configuration process, refer to the document "SIPLACE Explorer 2.11
Installation and Configuration Manual", Item No.: 00196800-04.
● Due to a restriction from the Microsoft DNS service, the name of the computer on which Tomcat is
installed must include no special characters, in particular no underscore (_). If the name does include
these characters, it will not be possible to display the website. For further details about this restriction,
see "http://support.microsoft.com/kb/275033".
22 of 48
SIPLACE Explorer 2.11 Ausgabe 10/2013 Edition
5 Installation
For detailed information about the installation and configuration process, refer to the document "SIPLACE
Explorer 2.11 Installation and Configuration Manual", Item No.: 00196800-04. This includes a description
of the installation process via the install shield wizard and details of manual configurations to be
performed.
23 of 48
SIPLACE Explorer 2.11 Ausgabe 10/2013 Edition
6 SIPLACE Error Reporting
SIPLACE Explorer V 2.11 provides SIPLACE Error Reporting, which can be used to record production
line errors which occur in SIPLACE Explorer and Tomcat. The files recorded can then be sent for error
analysis to service department.
The following files are compiled by SIPLACE Error Reporting.
● OIS/SIS database configuration information, such as database version number, line and station
names.
● Information about the production lines configured in SIPLACE Explorer.
● Log files from SIPLACE Explorer
● Log files from Tomcat 5.5x
● OIS/SIS databases,
● SIPLACE Explorer line databases
● SIPLACE Explorer factory databases
● Log Files
6.1 SIPLACE Explorer Log Files
The following SIPLACE Explorer log files are recorded:
● config\version.cfg
● config\lines.xml
● Lines\Line1\SMA.gms
● Automatic Production Reporting Application.log
● FactoryConfigurationUtility.log
● logs\dev.log
● logs\dev_error.log
● logs\dev_process.log
● logs\FactoryConfigurationUtility.log
● logs\manager.log
● logs\runtime.log
● logs\runtime_error.log
● logs\runtime_process.log
● logs\ErrorReporting.log
24 of 48