3.07 1.000 TP0803
TP0803TP0803
TP0803 8
88
8 Add
YSSeries
mounter,
__YG12__
Operation
Panel
Thefunctionwasaddedthatthefollowingoperationpanelbuttoncouldoperatethe
buttonofthemessagescreen.
1.Whenthemessagescreenhasonebutton,the[STOP]buttoncanoperateit.
2.Whenthemessagescreenhastwobuttons,the[START],[STOP]buttoncanoperate
it.
3.Whenthemessagescreenhasthreebuttons,the[START],[STOP]and[ERROR
CLEAR]buttoncanoperateit.
Thisfunctionisavailablewhenthe[Setting]-[SpecificationInformation]-[Panel
Specification]-[ButtonFunction]is"Extend".
Itismodified.
3.07 1.000 TT3560
TT3560TT3560
TT3560 9
99
9 Add Optimizer NozzleChange
Theoptimizationperformanceofthenozzlereturnactionwasimproved.
Thecycletimemightgetbettermorethan10%whentheboarddatahadmanynozzle
returnaction.
Itismodified.
3.07 1.000 TT3806
TT3806TT3806
TT3806 10
1010
10 Change
YSSeries
mounter
GUI
ThefollowingbuttonnamewaschangedontheYSseries.
1.Thenameofthe[Unit]-[Feeder]-[CartInformation]buttonischangedto[Plate
Information]button.
Itismodified.
3.07 1.000 TT3634
TT3634TT3634
TT3634 11
1111
11 Bug Mounter GUI
Whenoneorotherofthefollowingconditionswassatisfied,therewasabugthatthe
buttononthe[Unit]-[Conveyor]screenwasnotcorrespondingtothefunctional
behavior.
1.The[Setting]-[MachineInformation]-[InstallationSetting]-[ConveyorDirection]
is"L->R"andthe[Setting]-[MachineInformation]-[InstallationSetting]-[Twin
PushUp]is"Exit".
Whenthe[MainStopper],[PushUp]or[BoardClamp]buttonisclicked,theother
sidestagemoves.
2.Therearsideisselectedbythe[OperationPanel]-[ACTIVE]button,
Whenthe[Left]or[Right]buttonisclicked,theactualmovingdirectionisoppositeto
thearrowonthebutton.
Itisfixed.
3.07 1.000 TT3634
TT3634TT3634
TT3634 12
1212
12 Bug Mounter GUI
Whenthefollowingconditionsweresatisfied,therewasabugthattheconveyorarrow
onthe[Monitor]-[Production]screenwasdisplayedastheoppositedirection.
1.The[Setting]-[MachineInformation]-[InstallationSetting]-[ConveyorDirection]
is"L->R".
Itisfixed.
3.07 1.000 TT3538
TT3538TT3538
TT3538 13
1313
13 Bug Mounter Warmup
Whenthefollowingprocedureswereexecuted,therewasabugthatthemounter
stoppedsoonevenifwarming-upstarted.
1.Someerrormessagesaredisplayed,afterthattheerrormessagesscreenarehidden
bythe[Close]button.
2.Clickthe[Setup]-[WarmUp]-[Start]button.
Itisfixed.
3.07 1.000 TT3804
TT3804TT3804
TT3804 14
1414
14 Bug Mounter ErrorMessage
Whenthefollowingerroroccurredby[Setup]-[SystemBackup],therewasabugthat
thecontentsofthe[Drive]andthe[Connect]werenotdisplayed.
1.Ea2912-Ea2921:SYSTEMBACKUPERROR
2.Ea2927:SYSTEMBACKUPWARNING
Itisfixed.
3.07 1.000 TT3841
TT3841TT3841
TT3841 15
1515
15 Bug Mounter Coplanarity
Whenthefollowingprocedureswereexecuted,therewasabugthatthemounter
applicationabnormalendoccurred.
1.Selectthe[Setup]-[SoftwareSetting]-[Basic]-[Co-PlanarityChecker]-[3D
RecognitionResult]isexceptfor"NoSave".
2.CreatetheboarddatathatexecutestheCo-Planarityrecognition,andstartauto-
running.
3.The[Ea5leadnumbererror]erroroccurs.
4.Clickthe[ERRORCLEAR]button(NotexecuteReset).
5.Clickthe[Parts]-[PartsAdj]-[Test]button.
Itisfixed.
3.07 1.000 TT3840
TT3840TT3840
TT3840 16
1616
16 Bug Mounter Teach
Therewasabugthatthe[Jump]screencouldnotopenevenifthe[Jump]buttonwas
clickedintheteachscreen.The[Jump]buttonsofallteachscreenswereaffected.
Itisfixed.
3.07 1.000 TT3597
TT3597TT3597
TT3597 17
1717
17 Bug Mounter Trace
Whenthefollowingprocedureswereexecuted,therewasabugthatthemounter
applicationabnormalendmightoccur.
1.The[Setting]-[MachineInformation]-[InstallationSetting]-[TrayChanger]-
[TrayChangerType]is"None".
2.The[Parts]-[Basic]-[FeederType]is"Ext.TC"or"AutoTC".
3.Selectthepartsoftheabove2onthepartsinformationscreen,andclickthe
[Teach]-[Trace]button.
Itisfixed.
MDOC-VG30-00001 95/151

YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.
IMOperations
IMOperationsIMOperations
IMOperations
ReleaseNote(English) 2011/2/1
Ver
VerVer
Ver Rev
RevRev
Rev Num
NumNum
Num Ref
RefRef
Ref Item
ItemItem
Item Type
TypeType
Type Keyword
KeywordKeyword
Keyword Contents
ContentsContents
Contents Result
ResultResult
Result Doc
DocDoc
Doc
3.07 1.000 TT3344
TT3344TT3344
TT3344 18
1818
18 Bug Mounter Monitor
Therewasabugthatthefollowingitemsweredisplayedshorterthantheactualtime
whentheboardwasproducedwiththemarkrecognitionmorethantwice.
1.[Monitor]-[Main]tab
1)CycleTime
2.[Monitor]-[Detail]tab,MaxOutput:
1)board/h
2)block/h
3.[MIS]-[ProgramLog]tab
1)MarkRecCTMax
2)MarkRecCTMin
3)MarkRecCTAve
Itisfixed.
3.07 1.000 TT3706
TT3706TT3706
TT3706 19
1919
19 Bug Mounter Monitor
Whenthefollowingprocedureswereexecuted,therewasabugthatthemounter
applicationabnormalendoccurred.
1.Someofdialogscreenisdisplayed(e.g.,Click[Monitor]-[PickPosition]-[Current
Reset]button).
2.Someoferroroccurs,andtheerrordialogisdisplayed.(atthistime,thescreenis
transferredtothe[Monitor]-[Production]screen)
3.Closetheabove2dialog.
4.Whentheabove1dialogisclosed,theapplicationabnormalendoccurs.
Itisfixed.
3.07 1.000 TT3635
TT3635TT3635
TT3635 20
2020
20 Bug Mounter Randomball
TherewasabugthatthevalueoftheloadedRandomballwasnotdisplayedonthe
[Parts]-[PartsAdj]-[RandomBall]-[RandomBallEdit]screenwhentheBoarddata
oftheVIOSformatwasread.
Itisfixed.
3.07 1.000 TT3809
TT3809TT3809
TT3809 21
2121
21 Bug Mounter BoardOpen
Whenaboarddataofanymachinewaschangedinthe[Linecontrol]-[Boardchange],
therewasabugthatthemounterapplicationabnormalendoccurred.
Itisfixed.
3.07 1.000 TT3859
TT3859TT3859
TT3859 22
2222
22 Bug YS100,YS88 Feeder
TherewasabugthattheconnectionstatesoftheSSfeederswerenotdisplayedinthe
I/Oscreen.
TheconnectioninformationofLast8feedersofeachSSfeederplatewerenot
displayedinthe[Unit]-[I/O]-[Input]-[Feeder].
Itisfixed.
3.07 1.000 TT3848
TT3848TT3848
TT3848 23
2323
23 Bug
YS12,
__YG12__
Application
Whenthefollowingprocedureswereexecuted,therewasabugthatthe[Es00305:Soft
LimitOver]erroroccurredwhentheboardfiducialrecognizedatfirstproductionafter
poweron.
1.The[SoftwareSetting]-[History]-[DetailHistorySetting]-[RememberLotLog]is
"ON".
2.AveragemountingCTarerecordedwithmorethan"0"intherememberedlotlog.
Itisfixed.
3.07 1.000 TT3622
TT3622TT3622
TT3622 24
2424
24 Bug
YS12,
__YG12__
BaseFan
Therewasabugthattheabnormalityofthe[basefan4]couldnotbedetected. Itisfixed.
3.07 1.000 TT3787
TT3787TT3787
TT3787 25
2525
25 Bug
YSSeries
mounter
Feeder
Therewasabugthatthe[Ea29545:INTERLOCKERROR]rarelyoccurredalthoughthe
feederwasattachedonthemounter.Whenthemounterdidauto-running,the
productionwasstoppedbythiserror.
Itisfixed.
3.07 1.000 TT3815
TT3815TT3815
TT3815 26
2626
26 Bug Editor
GerberData
Conversion
Whenthegerberdataofinch-unitwereconvertedtomilli-unit,therewasabugthat
thegerberdatawasconvertedasinch-unit.
Itisfixed.
3.07 1.000 TT3565
TT3565TT3565
TT3565 27
2727
27 Bug Optimizer Fixedboard
Whenallofthefollowingconditionsweresatisfied,therewasabugthattheoptimizer
abnormalendoccurred.
1.Thetargetboardoftheoptimizationincludesthepartsthatfeedersetnumberis
fixed.
Whenoneorotherofthefollowing1)to4)issatisfiedforthefixcondition.
1)[Optimization]-[SetOptimizationParameters]-[BasicCondition]-[Exec
Condition]-[FeederSetCondition]is"AllPartsFixed".
2)[BoardEditor]-[Parts]-[Option]-[UseFeederOptimize]is"No".
3)[BoardEditor]-[Parts]-[Basic]-[Package]isnot"Tray"andthe[Pars]-[Pick]
-[PositionDefinition]is"Teaching".
4)[BoardEditor]-[Parts]-[Basic]-[FixComp.Ref]wasotherthan"0".
2.Thefixedboardincludesthepartsthathavesamepartsnameofabove1andsame
feedersetnumberofabove1.
3.Thepartsabove1havealternativeparts.
4.Thefixedboarddoesnotincludethepartsthatsatisfyallofthefollowingconditions.
1)Thepartsnameisthesameasthealternativepartsabove3.
Itisfixed.
3.07 1.000 TT3700
TT3700TT3700
TT3700 28
2828
28 Bug Optimizer Fixedboard
Whenthefollowingprocedureswereexecuted,therewasabugthattheoptimization
resultofthefeedersetpositionswereassignedtounexpectedfeedersetpositions.
1.UsetheFixedBoardfortheoptimization.
2.Executethefollowingproceduresonthe[Setoptimizationparameters]-[Detail]
screen.
1)[Setdetailoptimizationparameters]-[FixedBoard]-[Add]-(Selecttwoormore
boarddataattheboarddatalist)-[Select].
2)Executethe[Setdetailoptimizationparameters]-[FixedBoard]-(Selecttheboard
dataonotherthanlastrow)-[Delete],andthenclickthe[OK]button.
3)Withoutdeletingthefixedboardofabove2),theboardonthelastrowofthe[Set
detailoptimizationparameters]-[FixedBoard]listisdeleted.
Itisfixed.
MDOC-VG30-00001 96/151

YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.YAMAHAMOTORCO.,LTD.
YAMAHAMOTORCO.,LTD.
IMOperations
IMOperationsIMOperations
IMOperations
ReleaseNote(English) 2011/2/1
Ver
VerVer
Ver Rev
RevRev
Rev Num
NumNum
Num Ref
RefRef
Ref Item
ItemItem
Item Type
TypeType
Type Keyword
KeywordKeyword
Keyword Contents
ContentsContents
Contents Result
ResultResult
Result Doc
DocDoc
Doc
3.07 1.000 TT3321
TT3321TT3321
TT3321 29
2929
29 Bug Optimizer Optimization
Whenallofthefollowingconditionsweresatisfied,therewasabugthatthe
OptimizationortheCTestimationfailed.
1.ThepartsofdYTFexist.
2.InthepartsofdYTF,boththe[Parts]-[Pick]-[X(mm)]andthe[Y(mm)]are
"0.000".
Itisfixed.
3.07 1.000 TT3704
TT3704TT3704
TT3704 30
3030
30 Bug Optimizer
Alternative
parts
Whenallofthefollowingconditionsweresatisfied,therewasabugthattheoptimizer
abnormalendoccurred.
1.Thepartsissetownpartsnumberin[No.]inthe[Parts]-[Option]-[Alternative
Parts].
2.Otherthanabove1,thepartshasanyvalueinthe[Parts]-[Option]-[Alternative
Parts].
3.The[Setoptimizationparameter]-[BasicCondition]-[ExecCondition]-[Feeder
SetCondition]is"DistributeinLine".
4.Thelinehastwoormoremachines,theabovepartscanbedistributedtoany
machine.
Itisfixed.
3.08 1.000 TM1160
TM1160TM1160
TM1160 1
11
1
Important
ImportantImportant
Important
Add
AddAdd
Add
YSSeries
Mounter,
YG12
Vaccum
Backup
Thevacuumbackupfunctionhasbeenaddedasanoption.
Thisfunctioncontributestoimprovethemountingpartsaccuracybecausetheboard
fixingaccuracyisimproved.
Itismodified.
*
3.08 1.000 UD0688
UD0688UD0688
UD0688 2
22
2
Important
ImportantImportant
Important
Add
AddAdd
Add
Editor Boarddata
Thefollowingfunctionhasbeenadded.
Whenpartsinformationisdeletedon[Edit]-[Delete]-[Deletecommand]-[Delete
emptyLines],themountinginformationthatisusingthispartsinformationisdeleted
together.
Itismodified.
3.08 1.000 TT3665
TT3665TT3665
TT3665 3
33
3
Important
ImportantImportant
Important
Add
AddAdd
Add
Optimizer
Optimization
parameters
The"Heightdifferencetopermitovertaking"functionhasbeenaddedintheexecution
optionoftheoptimization.
Ithasbeenpossibletooptimizethatpartsareassignedinsmallorderoftheparts
thicknessfromtheupstreamlinetothedownstreamline,becausethisfunctioncan
obtainmountingpartswithacertainrangeofpartsheightforeachmountingstage.
Itismodified.
*
3.08 1.000 TT3954
TT3954TT3954
TT3954 4
44
4 CriticalBug
CriticalBugCriticalBug
CriticalBug Mounter Database
Therewasabugthat[Ea16263:Itfailedinwritingintothedatabase]wasdisplayedjust
afteranyofthefollowingitemswasedited.
1.[Parts]-[Basic]-[Database]-[Partsdataname]
2.[Parts]-[Basic]-[Database]-[Comment]
3.[Mark]-[Basic]-[Database]-[Markdataname]
4.[Mark]-[Basic]-[Database]-[Comment]
Itisfixed.
3.08 1.000 TT3881
TT3881TT3881
TT3881 5
55
5 CriticalBug
CriticalBugCriticalBug
CriticalBug Mounter Randomball
When"aboarddatathatusedrandomball"or"apartsdatabasethatusedrandom
ball"wasused,therewasabugthatthefollowingerroroccurredwhentherandomball
partswasrecognized.
1.Duringauto-running:[Ea31:PICKUPERROR]or[Ea33:COMPONENTDETECTION
ERROR]occurs.
2.[Parts]-[PartsAdj]-[Test]:[Ea2868:FAILEDTOSENDRANDOMBALLDATA]
occurs.
3.[Parts]-[PartsAdj]-[FindBest]:[Ea2868:FAILEDTOSENDRANDOMBALL
DATA]occurs.
Itisfixed.
3.08 1.000 TT3874
TT3874TT3874
TT3874 6
66
6 CriticalBug
CriticalBugCriticalBug
CriticalBug
YG12,YS12,
YS12P
ScanCamera
Whenthefollowingconditionwassatisfied,therewasapossibilityofnozzledamage
becausethenozzleinterferedwiththescan-camera.
1.Theservo-erroroccurswhentheX-axisismoving.(e.g.,Es00007:OVERCURRENT,
etc.)
Itisfixed.
3.08 1.000 TT3992
TT3992TT3992
TT3992 7
77
7 CriticalBug
CriticalBugCriticalBug
CriticalBug Optimizer CTEstimation
Whenthefollowingprocedureswereexecuted,therewasabugthatthe"Optimizer
applicationabnormalend"mightoccur.
1.UseYSseriesmachineequippedwithautoTC.
2.Usetheboarddataincludingthefollowingpartsinformation.
1)ThepartsAthat"AutoTC"isselectedon[Parts]-[Basic]-[FeederType].
2)ThepartsBthatissetasalternativeof1).
3.ExecuteOptimizationorCTestimation.
Itisfixed.
3.08 1.000 TM1296
TM1296TM1296
TM1296 8
88
8 Add Mounter Application
"MchlineoftheLotlogdoesnotoutput"hasbeenaddedon[Setup]-[Software
Setting]-[History]-[DetailHistorySetting].
Incaseofunnecessarytooutputwholemachinerowto"Lotlog",setthecheckboxto
"checkedstate".
Incaseofnecessarytooutputwholemachinerowandstagerowto"Lotlog"as
before,setthecheckboxto"uncheckedstate".
Itismodified.
*
3.08 1.000 TP1031
TP1031TP1031
TP1031 9
99
9 Add Mounter BoardOpen
Thefunctionhasbeenaddedthattheboarddatafoldercanbefixedwhenoperator
selectsboarddata.
Whenselectingboarddatathatfoldersometimeschangedunexpectedlyandifthereare
morethanonesameboardnameinseveralfolders,operatormightselectwrongboard
data.
Forpreventingthesemistaketoselectbarddata,thefunctionthatfolderdirectoryis
fixedhasbeenadded.
Itismodified.
*