5. Error Message
The table below is the error messages added for this function.
Error Message List
No. Title Cause and Solution
7573
Nozzle Health Check is
completed.
No abnormal nozzle was detected.
7574
Nozzle Health Check is
completed.
Abnormal nozzle was detected.
For details, refer to the [Monitor] - [Nzle Hlth Chk] screen.
7575
Abnormality detected at
Nozzle Health Check.
An abnormality was detected at Nozzle Health Check, so
that auto-running is not started.
Refer to the [Monitor] - [Nzle Hlth Chk] screen.

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD
MDOC-SOFT50394
12/13
7576
Abnormal Vacuum
detected.
Detection Rate (%) is larger than Error Detection Rate
(%).
A nozzle may be clogged.
・Clean or change the nozzle and shaft.
・Confirm the value of Error Detection Rate on [Machine]
- [Schedule Spec] - [Vacuum Check].
・Confirm the Low level and High level of [Machine] -
[Vacuum Level].
* For details of "Detection Rate" and "Error Detection
Rate", refer to the [Detail] tab.
------------------------------------------------
- "Detection Rate" means "clog level" of a nozzle,
compared to the difference between "Max Vacuum Level"
and "Min Vacuum Level" as 100.
Detection Rate(%) = ( Current Vacuum Level - Min
Vacuum Level ) / ( Max Vacuum Level - Min Vacuum
Level ) ×100
- "Min Vacuum Level" means Low Level, and "Max
Vacuum Level" means high level.
- "Error Detection Rate" is the value set on [Machine] -
[Schedule Spec] - [Vacuum Check].
The error occurs when "Detection Rate" is over this
value.
7577
Nozzle tip dirt detected. Abnormality detected on the tip of a nozzle.
It may be unclean or damaged.
7578
Abnormal nozzle buffing
detected.
There is something wrong with the nozzle buffing.
The buffing may be unclean, sticky, or jammed.
7579
Abnormal nozzle shape
detected.
There is something wrong attached on a nozzle.
Clean or change it.

SMT Software Engineering Group
IMOperationsYAMAHAMOTORCO.,LTD
MDOC-SOFT50394
13/13
7580
Abnormal nozzle
alignment detected.
Misalignment of nozzle tip position is over the correction
limit.
The nozzle may be damaged, unclean, or skewed.
7581
Unable to perform
nozzle health check.
It is necessary to read board data, when "ManualNzlChg"
is selected.
Read board data, or
Select "AutoNzlChg" on [Machine] - [Machine Data] -
[Head] - [Head Offset].
7584
Board data has been
edited.
Save and reload the board data to apply the changes.
7585
Nozzle Health Check
failed.
Confirm the following, and try it again.
・ There is nothing wrong with the machine.
・ Machine setting is correct.
7590
Nozzle Health Check
Execution Error
Unable to execute Nozzle Health Check with [board data
nozzle] because the board data has an error.
Reload the board data and remove the cause of the error.
7591
Nozzle Health Check
Execution Error
Unable to execute Nozzle Health Check with [board data
nozzle] because board data is not read.
Read board data.
7592
Nozzle Health Check
Execution Error
Unable to execute Nozzle Health Check with [NG Nozzle]
because there is no NG nozzle.