00198611-02_IM_712.1_R19-1_EN.pdf - 第15页
Station Software Version 7 12.1 (R19-1) / Installation Manual 05/2019 Edition 15 4 Requirements 4.1 Software Components of SIPLACE Series X, X S, SX, DX, CA and TX 4.1.1 Station – Microsoft .NET 4.6.1 (must be installed …

Station Software Version 712.1 (R19-1) / Installation Manual 05/2019 Edition
14
Figure 3-7: Adjusting inspection options
3.10 Upgrading from the 705.xx Software Version
► If necessary, perform an upgrade to the Microsoft Windows Embedded Standard 7 (WES7,
32-bit or 64-bit) operating system. Please refer to sections 4.1.1 and 5.3.1.
► SX1/SX2 and DX1/DX2 placement machines in the field with an FC camera at Location 1:
Due to an error correction in the configuration, the FC camera position has been moved and
thus the calibration values for the camera and the segment offset are invalid.
Recalibrate the camera and the segment offset.

Station Software Version 712.1 (R19-1) / Installation Manual 05/2019 Edition
15
4 Requirements
4.1 Software Components of SIPLACE Series X, X S, SX, DX, CA and
TX
4.1.1 Station
– Microsoft .NET 4.6.1 (must be installed manually)
– The station only uses one of the following operating system configurations on the station
computer and Coplan computer/feeder computer:
– Microsoft Windows Embedded Standard 7 (WES7, 32-bit or 64-bit)
– Microsoft Windows 10 IoT (Win10), 64-bit on TX-series placement machines
The station computer must be equipped with at least 2 GB memory (RAM) with WES7, 32-bit
and 4 GB memory (RAM) with WES7 and Win10, 64-bit respectively. If necessary, station
computers in the field must be exchanged or upgraded with a memory extension. Please refer
to the Technical Information TI2014-09E04.
4.1.2 Machine Components
The following versions of other machine components are required for the station software to
function correctly:
SIPLACE station software
SIPLACE Vision
SIPLACE Pro
Version 712.1
*)
Version 5.6.2
Version 16.1
**)
*)
in compatible mode: Version 711.2©
**)
in compatible mode: SIPLACE Pro 15.x
CAUTION
The functional statuses of the station computer, Vision computer and SIPLACE Pro
software must be compatible, as specified above. Another configuration is not supported.

Station Software Version 712.1 (R19-1) / Installation Manual 05/2019 Edition
16
4.1.3 Embedded Software
4.1.3.1 Composition of the File Name
1..6
7
8
9
10
11
12
13
14
15
16
17
18
19
Sub-
system
name
Sepa-
rator
Variant ID
Hard-
ware ID
1)
Target
2)
Version
Release
.
File type
Please
refer to
table in
section
4.1.3.2
_
0 = no
variant
00
0 = BIOS
00
H
00
H
.
HEX
_
A =
Variant
(SOKO)
…
…
…
…
.
JED
_
...
99
9 = App 9
FF
H
FF
H
.
BHX
Table 4-1: Composition of the file name
1)
Change compared with old file name (from one to 2 digits)
2)
Extended to second CAN