YS100_Ope_E.pdf - 第73页
2-6 2 asic operation n Data-related errors Code Error name and description Ea00036 V ACUUM LEVEL ERROR State V acuum level has not reached the specified level. The component might have dropped after recognition. Cause …

2-5
2
asic operation
n
Conveyor-related errors
Code Error name and description
Ea00070
BOARD TRANSFER ERROR
State Unexpected board is on the conveyor.
Cause
Board was carried in from upstream side even though no board request signal was output, or an abnormal
board was detected.
Action
Readjust the position of conveyor exit sensor on upstream side, or the position of conveyor carry-in sensor or
board detection sensor at the entrance stopper of this machine.
Ea00074
BOARD FIXING ERROR
State Board trans-unit, locate pin or push-up unit does not respond to command.
Cause Senor position adjustment is inappropriate, or speed control is set too low to maintain stable movement.
Action Check the sensors for conveyor unit height to see if they are operating properly.
Ea00831
MAIN STOPPER INTERLOCK
State
Operation of the main stopper in this table height cannot be performed.
-Please lower the Board table.
Or You can't move table on dangerous position, because the main stopper is upper.
-Please move main stopper down.
Cause Main stopper is raised, creating a dangerous situation.
Action Lower the main stopper.
Ea00851
INTERLOCK ERROR
State Transfer axis up/down sensor is OFF. Remove the cause of this sensor being OFF.
Cause Board conveyor unit is left lowered, or sensor error occurred.
Action Check the conveyor unit for up/down movement.
Ea00852
INTERLOCK ERROR
State The sensor for main stopper, push-up or entrance stopper is ON. Remove the cause of this sensor being ON.
Cause Sensor is defective or actuator operation is poor.
Action Check the conveyor unit for up/down movement.
Ea07876
CAN NOT EXECUTE COMMAND
State
Failed to execute this command, because the push-up unit's position is not enough low. Please execute this
command after moving it down again,
Cause Unable to run this command since servo push-up is not sufficiently lowered.
Action Lower the servo push-up by conveyor unit operation or reset, then re-run this command.

2-6
2
asic operation
n
Data-related errors
Code Error name and description
Ea00036
VACUUM LEVEL ERROR
State Vacuum level has not reached the specified level. The component might have dropped after recognition.
Cause
Pickup vacuum pressure is not appropriate, or component is not correctly picked up. Component pickup
position coordinate is inaccurate or pickup accuracy is poor.
Action
Make adjustment so that the component is picked up properly, then readjust the pickup vacuum pressure in
Adjust mode.
Ea00267
FIDUCIAL FINE CORRECTION ERROR
State
Failed to adjust the XY position for FINE mode within limit. The limit is specified as FINE mode in machine
data.
Cause Correction range is too narrow.
Action Widen the correction range.
Ea00502
DATA READING ERROR
State Failed to read data.
Cause File may be destroyed.
Action Relevant data cannot be loaded. If backup data is available, copy and load it.
Ea00503
BOARD DATA ERROR
State Failed to write data.
Cause Hard disk is full or disk has errors.
Action First check the disk condition. If the number of files is too high, reduce the number of files, then retry.
Ea02702
NOZZLE STATION MACS ERROR
State Failed to execute Nozzle Station MACS. Please check the machine data, and mark data in mark database.
Cause Failed to recognize marks while recognizing nozzle station MACS to perform a nozzle change.
Action Correct the positions of nozzle station MACS, or set the correct mark database No.

2-7
2
asic operation
n
Feeder
-related errors
Code Error name and description
Ea03952
Feeder Pitch is not set to the following parts data.
State Feeder Pitch is not set to the following parts data.
Cause Feeder Pitch is not set to the following parts data.
Action Check the parts data and set correct Feeder pitch.
Ea30100
Feed Not Completed
State Feeder could not finish feeding parts when the head reaches parts.
Cause
Feed timer setting is too short compared to the possible feed time, or it took time to drive the feeder due to an
accidental cause.
Action Please confirm whether never to hinder the feeding operation.
Ea30101
Feeder does not Exist.
State The feeder cannot be detected. Please confirm the set position of feeder.
Cause The feeder cannot be detected. Please confirm the set position of feeder.
Action
Please comfirm the feeder set.
If feeder is attached but this error occurred. Please check the feeder status on [UNIT]-[FEEDER] screen.
If feeder exist but data is not correctly read,
Push the [RELOAD] button on [Unit]-[Feeder] screen, then confirm the feeder data is correctly read, or clear
this error and wait for 10 seconds then restart the machine.
Ea30102
Feeder Error State
State Because the error occurs by the feeder, the feeding operation cannot be executed.
Cause Because the error occurs by the feeder, the feeding operation cannot be executed.
Action
Please confirm the state of the feeder.
Please remove the cause of the error, and set the feeder again once.
Ea30106
Feeder Control Board detection error.
State Feeder control board could not be detected.
Cause Feeder control board could not be detected.
Action
Please confirm the state of electric contact of the feeder cart.
The feeder cart state can be confirmed from feeder cart LED.
When this error occurs repeatedly, the breakdown of the feeder cart board is thought.