AG − 900+ and AG900+S Applicators 9  2009 Nordson Corporation Part 1098464A First Aid If molten hot melt comes in contact with your skin: 1. Do NOT attempt to remove the molten hot melt from your skin. 2. Immediately so…

100%1 / 56
AG900+ and AG900+S Applicators
8
Part 1098464A
2009 Nordson Corporation
Table 1: General Safety Warnings and Cautions (contd)
Equipment
Type
Warnings and Cautions
HM
CAUTION! Hot surfaces! Avoid contact with the hot metal
surfaces of guns, hoses, and certain components of the
melter. If contact can not be avoided, wear heat-protective
gloves and clothing when working around heated equipment.
Failure to avoid contact with hot metal surfaces can result in
personal injury.
HM
CAUTION! Some Nordson melters are specifically designed to
process polyurethane reactive (PUR) hot melt. Attempting to
process PUR in equipment not specifically designed for this
purpose can damage the equipment and cause premature
reaction of the hot melt. If you are unsure of the equipment’s
ability to process PUR, contact your Nordson representative
for assistance.
HM, CA
CAUTION! Before using any cleaning or flushing compound
on or in the equipment, read and comply with the
manufacturer’s instructions and the MSDS supplied with the
compound. Some cleaning compounds can react
unpredictably with hot melt or cold adhesive, resulting in
damage to the equipment.
HM
CAUTION! Nordson hot melt equipment is factory tested with
Nordson Type R fluid that contains polyester adipate
plasticizer. Certain hot melt materials can react with Type R
fluid and form a solid gum that can clog the equipment. Before
using the equipment, confirm that the hot melt is compatible
with Type R fluid.
Other Safety Precautions
Do not use an open flame to heat hot melt system components.
Check high pressure hoses daily for signs of excessive wear, damage, or leaks.
Never point a dispensing handgun at yourself or others.
Suspend dispensing handguns by their proper suspension point.
AG900+ and AG900+S Applicators
9
2009 Nordson Corporation
Part 1098464A
First Aid
If molten hot melt comes in contact with your skin:
1. Do NOT attempt to remove the molten hot melt from your skin.
2. Immediately soak the affected area in clean, cold water until the hot melt has cooled.
3. Do NOT attempt to remove the solidified hot melt from your skin.
4. In case of severe burns, treat for shock.
5. Seek expert medical attention immediately. Give the MSDS for the hot melt to the
medical personnel providing treatment.
AG900+ and AG900+S Applicators
10
Part 1098464A
2009 Nordson Corporation
Description
See Figure 1. The Nordson AG-900+/AG900+S modular dispensing applicator is a
noncirculating unit that applies solid and foamed high performance materials such as
silicones, plastisols, urethanes, epoxies, butyls and hot melts. The applicator is compatible
with a variety of Nordson systems and is well suited for automated dispensing equipment.
1
6
5
3
4
8
7
2
Figure 1: AG-900+ Dispensing Applicator with ZeroCavity Nozzle
1. Applicator module
2. Adapter block
3. Needle
4. Pressure regulated material
5. Air-close port
6. Piston
7. Air-open port
8. Needle/nozzle assembly
The applicator is pneumatically triggered by a customer supplied external solenoid. The
applicator assembly includes a module, and either a pressure regulator (heated or
unheated) or applicator adapter body.
The AG-900+/AG900+S dispensing applicator is available as a zero cavity needle/nozzle
design, or can be provided to accept standard extrusion nozzles.