15 OM-1683 (7) Open the transparent cover . CAUTION The load power to the motors, etc., is turned OFF but the setup operation must be performed carefully when you put your hand inside the machine. Avoid handandngerin…

14
OM-1683
7.1 ConrmationofPCBTransferandPositioning
The following describes how to check the status of the PCB transfer and
positioning in the "PCB XFER" window (a menu of "AUTO OPN").
Procedure
(1) Display the "PCB XFER" window using the following icon procedure.
Fig. 15
(2) Send the PCB in the lane where the PCB transfer and positioning status are
conrmed with the input machine.
(3)
Select a desired block button (expressed graphically) for "PCB LOCATE 1".
In 10 seconds, press the [START] button on the operation panel to transfer
the PCB.
(4)
Conrm that the PCB can be transferred normally and move smoothly
without falling down during the transfer.
(5)
Press the [Execute] button (entitled "PCB LOCATE L").
In 10 seconds, press the [START] button on the operation panel.
(The backup base moves up. )
(6)
Press the cover lock switch to turn off the lamp.
(The transparent cover is unlocked. )
1103-001
7.1ConrmationofPCBTransferandPositioning

15
OM-1683
(7) Open the transparent cover.
CAUTION
The load power to the motors, etc., is turned OFF
but the setup operation must be performed carefully
when you put your hand inside the machine. Avoid
handandngerinjuries.
(8) Slightly push the PCB by nger to conrm that there is no problem in the
location of the support pins.
(
9) Close the transparent cover.
(10) Press the cover lock switch to turn on the lamp.
1103-001
7.1ConrmationofPCBTransferandPositioning

16
OM-1683
8. "PCB.CNT." Window
This window enables the operator to set the PCB production count for each
lane.
Reference
Refer to "8. "PCB.CNT." Window" in Chapter 6, Volume 2, in the
SIGMA-G5 main machine instruction manual for the information other
than for dual transfer.
[1]
Fig. 16 PCB. CNT.
[1] Count
A Lane, B Lane
The number of produced PCBs for each lane for stopping the machine using
the PCB Counter Stop Mode, is set in this group box.
Note
The set count is displayed in the "Count" data box in the "AUTO. OPN"
window.
Graphic
Development
1103-001
8. "PCB.CNT." Window