GEM Manual for DEK Printers SECS II Implementation Issue 1.6 January 22, 2018 Page 67 of 171 units Units identifier. ‘s’ = seconds ‘cs’ = centiseconds ‘ms’ = milliseconds ASCII*  UPPERDB A variable li mit attribute tha…

100%1 / 171
GEM Manual for DEK Printers SECS II Implementation
Issue 1.6 January 22, 2018 Page 66 of 171
SOFTREV Software revision code. “V” MM ”R” mm
MM = Major version level.
mm = Minor version level.
ASCII*6
STIME Sample time. Yymmddhhmmss or
Yyyymmddhhmmsscc
ASCII*12 or
ASCII*16
Depends on
variable
TimeFormat
STRACK Spool stream acknowledge. 1 = Spooling illegal for stream.
e.g. stream 1
2 = Unknown stream.
3 = Unknown function for this
stream.
4 = Secondary function
specified for this stream.
binary*1
STRID Stream identity. Any supported stream number.
unsigned int*1
sv Status variable value. See chapter 7, Machine
Variables.
Depends upon
variable id.
svid Status variable identity. See chapter 7. unsigned int*4.
svname Status variable name. See chapter 7. ASCII* 
text Character string for terminal display.
Any printable characters. ASCII* 
tiaack Trace request acknowledge code. 0 = Acknowledge, OK.
1 = Too many SVID’s.
2 = No more traces allowed.
3 = Invalid period.
binary*1
tiack Time send acknowledge code. 0 = Accepted
1 = Error
binary*1
tid Terminal number. 0 = Single terminal. binary*1
Time Time of day. Yymmddhhmmss or
Yyyymmddhhmmsscc
1
ASCII*12 or
ASCII*16
Depends on
variable
TimeFormat
totsmp Total number of samples to be taken. 0-4294967295 unsigned int*4
trid Trace requests identity. 0-4294967295 unsigned int*4
1
If yy is less than 96 then yy is assumed to be 2000 + yy
GEM Manual for DEK Printers SECS II Implementation
Issue 1.6 January 22, 2018 Page 67 of 171
units Units identifier. ‘s’ = seconds
‘cs’ = centiseconds
‘ms’ = milliseconds
ASCII* 
UPPERDB A variable limit attribute that defines the
upper boundary of the deadband of a limit.
The value applies to a single limit
(LIMITID) for a specified VID.
Thus, UPPERDB and LOWERDB as a pair
define a limit.
See Variable limits section 5.5 Depends on the
type of the
variable.
v Variable data. See chapter 5, Machine
Variables.
Depends upon
variable id.
vid Variable identity. See chapter 5, Machine
Variables.
unsigned int*4.
VLAACK Variable limit attribute acknowledge code. 0 = Command will be done.
1 = Attribute definition error.
2 = Cannot do now.
binary*1
GEM Manual for DEK Printers SECS II Implementation
Issue 1.6 January 22, 2018 Page 68 of 171
5.3 STREAM 1: EQUIPMENT STATUS
S1F1 Are You There Request (R)
S1F2 On-Line Data (D)
Description: This transaction determines whether the receiver is alive and able to
respond. It can also trigger transition to the ON-LINE control state.
A. Host Initiated
Host to equipment: S1F1
Structure: Header only
Equipment to host: S1F2
Structure: L,2
1. <MODLN>
2. <SOFTREV>
B. Equipment Initiated
Equipment to host: S1F1
Structure: Header only
Host to equipment: S1F2
Structure: L,0