GEM Manual for DEK Printers SECS II Implementation
Issue 1.6 January 22, 2018 Page 93 of 171
S6F15 Event Report Request (ERR)
S6F16 Event Report Data (ERD)
Description: The host can use this transaction to demand a specified report group from
the equipment. Note that discrete data variables will have indeterminate values.
A. Host Initiated
Host to equipment: S6F15
Structure: <CEID>
Equipment to host: S6F16
Structure: Identical to S6F11.
Exception: A zero length list indicates there are no reports linked to the
specified CEID.
B. Equipment Initiated - Not applicable.
S6F19 Individual Report Request (IRR)
S6F20 Individual Report Data (IRD)
Description: The host can request a defined report to send. The report does not have to
be linked to a CEID, therefore no CEID are required to be enabled.
A. Host Initiated
Host to equipment: S6F19
Structure: <RPTID>
Equipment to host: S6F20
Structure: L,n ; n = No. of variable data items
1.<V1>
.
.
n. <Vn>
Exception: If n = 0 then the report RPTID does not exist.
B. Equipment Initiated - Not applicable.
GEM Manual for DEK Printers SECS II Implementation
Issue 1.6 January 22, 2018 Page 94 of 171
S6F23 Request Spooled Data (RSD)
S6F24 Request Spooled Data (RSDAS)
Description: The purpose of this message is for the host to request transmission or
deletion of the messages currently spooled by the equipment.
A. Host Initiated
Host to equipment: S6F23
Structure: <RSDC>
Equipment to host: S6F24
Structure: <RSDA>
B. Equipment Initiated - Not applicable.
GEM Manual for DEK Printers SECS II Implementation
Issue 1.6 January 22, 2018 Page 95 of 171
5.7 STREAM 7: PROCESS PROGRAM MANAGEMENT
S7F1 Process Program Load Inquire (PPI)
S7F2 Process Program Load Grant (PPG)
Description: This message is used to initiate the transfer of a process program. It’s use,
by the host, is optional.
A. Host Initiated
Host to equipment: S7F1
Structure: L,2
1. <PPID>
2. <LENGTH>
Equipment to host: S7F2
Structure: <PPGNT>
Exception: If LENGTH = 0 or different format then the LENGTH will be
ignored.
B. Equipment Initiated
Equipment to host: S7F1
Structure: L,2
1. <PPID>
2. <LENGTH>
Host to equipment: S7F2
Structure: <PPGNT>