00198788-01_UM_SSI_DE_EN.pdf - 第49页

4 Operation 4.4 Table adapter User Manual / Bedienungsanleitung SIPLACE Single Slot Interface 05/2021 49 4.4 Table adapter If you want to use the SSI for pre-setup, it can be fitted to a table adapter. This increases the…

100%1 / 60
4 Operation
4.3 Removing the feeder module
48 User Manual / Bedienungsanleitung SIPLACE Single Slot Interface 05/2021
4.3 Removing the feeder module
WARNING
Risk of body parts being trapped at the locking latch
To unlock, only press against the locking latch from below. There is a risk of limbs being
trapped at the locking latch.
You need to disconnect the power pack from the mains power before disconnecting the feeder
module from the SSI.
Hold the feeder module in the SSI with
one hand.
The locking lever (2)
is still engaged
and the locking latch (1)
points down-
wards (A)
.
With the other hand, press the locking
latch (1)
up and hold it in this position
(B)
.
 CAUTION!
When pressing the locking latch (1)
up, only hold it on the underside.
There is otherwise a risk of limbs
being trapped.
.
Pull the feeder module on the omega
rail back and out.
Let go of the locking latch (1) as soon
as the locking lever (2)
is exposed.
4 Operation
4.4 Table adapter
User Manual / Bedienungsanleitung SIPLACE Single Slot Interface 05/2021 49
4.4 Table adapter
If you want to use the SSI for pre-setup, it can be fitted to a table adapter. This increases the stabil-
ity of the equipment and give the component reel a fixed place.
WARNING
Injury from falling parts
The assembly must be correctly placed on the table to prevent it falling down and causing
any injuries.
Sales number: 00120672-xx
Fig.2: SSI table adapter
1 Führungsprofil links 2 Guide profile, right
3 Reel arm 4 Axis for accommodating the component
reel
A Knurled screw, back B Knurled screw, front
Fasten the SSI to the table adapter:
Loosen the back knurled screw (A) until
it is only slightly in the base plate.
Loosen the front knurled screw (B)
completely.
4 Operation
4.5 Preparation table
50 User Manual / Bedienungsanleitung SIPLACE Single Slot Interface 05/2021
Position the SSI between the guide
profiles and push it towards the back
knurled screw until half the drilled hole
(A)
on the SSI frame profile is against
the knurled screw.
Tighten the knurled screw.
Insert the other knurled screw through
the front drilled hole (B)
in the frame
profile and into the hole drilled in the
table adapter.
Tighten the knurled screw.
4.5 Preparation table
Multiple feeder modules can be set up (pre-setup) on one preparation table at the same time. At
the same time, an SSI can be fitted to the side of the preparation table.
WARNING
Injury from falling parts
The assembly must be correctly placed on the preparation table to prevent it falling down
and causing any injuries.
Sales number: 00120670-xx
Fig.3: Preparation table