IT Feeder Manual-SM320(English V2.0)Ver1.pdf - 第33页
IT Feeder System 1-21 Selected Feeder . ③ Set up a separate limit count in the <Selected Feeder>. First, select the feeder for which the limit count is to be set. Check if the selected feeder and part…

Samsung Intelligent Feeder System
Figure 1-21. Part Shortage Warning
①
②
③
④
Figure 1-22. Setup Part Shortage Warning
Shortage Warning Setup
① Check the <Enable Warning> check box to indicate whether to use the
remaining quantity warning function. If it is checked, the shortage warning
occurs.
② Select the <Count Limit Type>
All by One: This type is applied to all feeders downloaded in the program. If
the Apply Now button is pressed after entering the Limit Part Count, the
count limit is setup for all feeders.
By PCB: Checks the remaining quantity by multiplying the part quantity
with the PCB quantity. The set limit count varies according to the number of
parts used per PCB.
For setting up a separate limit count for each feeder, refer to the following
1-20

IT Feeder System
1-21
Selected Feeder.
③ Set up a separate limit count in the <Selected Feeder>.
First, select the feeder for which the limit count is to be set.
Check if the selected feeder and part information are correct.
Select the <Enable Change warning count limit> check box.
The checked setup corresponds only to the corresponding feeder slot.
Therefore, it does not vary for other feeder slots.
Confirm the current count and enter the desired quantity in the Limit count.
The procedure to restore the Mismatch Error is as follows.
Once the Limit count input is completed, press the <Change> button to set
the count.
Reference
The Limit Count that is set up in the Selected Feeder is not changed by the setup through
‘All by One’ and ‘by PCB’. Therefore the user should be careful of this. If it is desired to
make the contents set up in the Selected Feeder identical to those of other feeders, click
the corresponding slot and press the Reset button.
Now, the Shortage Warning setup is completed. In case the remaining part
quantity becomes equal to or less than the Shortage Limit count during operation,
the machine indicates warning via the lamp and screen.
1.4.8.2. Generation of Part Shortage Warning
If the Part Count becomes less than the Shortage Limit, the ITFS generates a warning.
Then the green lamp flickers and the green icon of the displayed machine icons
(
) flickers. The IT Feeder Manager yellow mark is indicated
in the slot where the Shortage Warning has occurred.

Samsung Intelligent Feeder System
Figure 1-23. IT Feeder Manager - Shortage Warning screen
The Shortage Warning can be disabled in two ways.
Disable the warning of the corresponding slot in the Shortage Warning window.
Prepare additional part reel and splice the two part reels.
Refer to [1.4.10 Splicing Part Reel].
Reference
Disable of Shortage
In the Shortage Warning dialog box in Figure. 1-23, select and check the slot where the
shortage warning occurs. For the check marked slot, the shortage warning is not
indicated.
1-22