IT Feeder Manual-SM320(English V2.0)Ver1.pdf - 第34页
Samsung Intelligent Feeder System Figur e 1-23. IT Feeder Manager - Shortage W arning scr een The Shortage W arning can be disabled in two ways. Disable the warning of the corresponding slot in the Shortage W arning …

IT Feeder System
1-21
Selected Feeder.
③ Set up a separate limit count in the <Selected Feeder>.
First, select the feeder for which the limit count is to be set.
Check if the selected feeder and part information are correct.
Select the <Enable Change warning count limit> check box.
The checked setup corresponds only to the corresponding feeder slot.
Therefore, it does not vary for other feeder slots.
Confirm the current count and enter the desired quantity in the Limit count.
The procedure to restore the Mismatch Error is as follows.
Once the Limit count input is completed, press the <Change> button to set
the count.
Reference
The Limit Count that is set up in the Selected Feeder is not changed by the setup through
‘All by One’ and ‘by PCB’. Therefore the user should be careful of this. If it is desired to
make the contents set up in the Selected Feeder identical to those of other feeders, click
the corresponding slot and press the Reset button.
Now, the Shortage Warning setup is completed. In case the remaining part
quantity becomes equal to or less than the Shortage Limit count during operation,
the machine indicates warning via the lamp and screen.
1.4.8.2. Generation of Part Shortage Warning
If the Part Count becomes less than the Shortage Limit, the ITFS generates a warning.
Then the green lamp flickers and the green icon of the displayed machine icons
(
) flickers. The IT Feeder Manager yellow mark is indicated
in the slot where the Shortage Warning has occurred.

Samsung Intelligent Feeder System
Figure 1-23. IT Feeder Manager - Shortage Warning screen
The Shortage Warning can be disabled in two ways.
Disable the warning of the corresponding slot in the Shortage Warning window.
Prepare additional part reel and splice the two part reels.
Refer to [1.4.10 Splicing Part Reel].
Reference
Disable of Shortage
In the Shortage Warning dialog box in Figure. 1-23, select and check the slot where the
shortage warning occurs. For the check marked slot, the shortage warning is not
indicated.
1-22

IT Feeder System
1-23
Figure 1-24. Shortage warning dialog
1.4.9. Mismatch Error
IFS provides two Mismatch Errors: Empty Feeder Error and Mismatch Feeder Error.
Empty Feeder Error
The Empty Feeder Error occurs when the feeder is not installed properly in the feeder
slot arranged by the PCB Program. Since this indicates that the corresponding slot is
empty, only the lamp turns on and it is not indicated in the IT Feeder Manager.
The red icon in the SM320 MMI screen and the red lamp of the machine are
flickering.
Figure 1-25. Mismatch indication in the SM320