IT Feeder Manual-SM320(English V2.0)Ver1.pdf - 第63页

Part S tation 2-23 ⑤󰚟 If the button is pressed, the New Part Import screen is displayed as shown below .  Select All : S elects all parts.  UnSelect All : Cancels all parts.  Inverse : Reverse the selected part.  De…

100%1 / 92
Samsung Intelligent Feeder System
③󰚟 Press the
button to import the Bom File and set the file format.
Then click the <OK> button.
④󰚟 If the searched part does not exist in the DB as shown in the following figure,
‘No Part’ is indicated and the
button is enabled.
2-22
Part Station
2-23
⑤󰚟 If the button is pressed, the New Part Import screen is displayed as
shown below.
Select All : Selects all parts.
UnSelect All : Cancels all parts.
Inverse : Reverse the selected part.
Description : Enters additional description.
Import : Register the selected part.
Cancel : Cancel the performed work.
⑥󰚟 If the <Import> button is clicked, the following dialog box is displayed and the
part is registered.
3. Part deletion
①󰚟 After executing the Part Information (F2) submenu, select the Option menu as
shown in the following figure and choose the Users Change (F11) submenu.
②󰚟 The following figure appears. Select the Administrator and enter the Password.
Samsung Intelligent Feeder System
③󰚟 Select the part to be deleted and delete it using the
button.
2-24