YS100_Ope_E.pdf - 第156页

Appendix Appendix Contents A1. Specifications A- 1

100%1 / 159
3-30
3
Starting and ending production
3.11 Coplanarity checker
Monitor: Co-PlaCheck (Coplanarity Check)
24319-L1-00
Head No.
Displays the head number currently being used.
Parts No.
Displays the part number currently being used.
Parts Name
Displays the part name currently being used.
Co-pla. Threshold [μm]
Displays the coplanarity tolerance that was set in parts information.
Error Number
Displays coplanarity error numbers.
Pass Count
Displays the number of images that were captured during coplanarity check.
Max. Co-planarity Pos.
Displays the lead number that was measured as the maximum coplanarity value.
Min. Co-planarity Pos.
Displays the lead number that was measured as the minimum coplanarity value.
Max-Min Co-planarity [μm]
Displays the coplanarity measurement result.
Co-planarity Max. [μm]
Displays the maximum coplanarity value.
Co-planarity Min. [μm]
Displays the minimum coplanarity value.
Recognition Height
Displays the recognition height (height to underside of components).
Appendix
Appendix
Contents
A1. Specifications A-1
A-1
Appendix
A1. Specifications
n
YS100 specifications
Item Specifications
Operating ambient temperature
Function guaranteed: 15 to 35°C
Accuracy guaranteed: 20 to 28°C
Operating ambient humidity 20 to 90% (no condensation), optimal range: 50 to 60%
Noise level Under 78dB
Power requirement (voltage and frequency) 3-phase AC 200/208/220/240/380/400/416 V ± 10%, 50/60 Hz
Average power consumption 0.75kW
Power cable (conductor cross-section area) 2.5 mm
2
or more
Overvoltage category *
1
Category III
Pollution degree *
1
Degree 2
Supply air pressure *
2
0.45MPa
Air flow rate *
6
110 Nl/min., Instantaneous maximum flow rate: 290 Nl/min.
Board transport height *
3
900 mm ± 10 mm
Data
Number of mounting points *
4
10,000 points
Number of part types 255 types per board
Number of fiducial marks *
5
128 sets per board
*1: Conforms to IEC60664-1.
*2: Clean, dry air passed through an air dryer and filter.
*3: Distance from the floor surface to the upper surface of conveyor belt.
*4: Decreases with the number of boards, blocks and fiducial marks.
*5: When using 2-point fiducial mode.
*6: Air flow rate is for machines with a tape cutter. (Includes 10 Nl for tape cutter.)
c

Conveyor's board sensors may fail to detect a production board if it has a slit or cutout.
n
NOTE
For more detailed information not listed above, please refer to specification sheets.