00197193-02_IM_SIPLACE_EDM_2.1_EN.pdf - 第55页

EDM V2.1 / I nstallat ion Ma nual Ausgabe 11/2012 E dition 55 Type: Path Default: [AppDir] \ help Valid for: Line serv er Master ser ver Clearing pool EDM Tool Descripti on: Folder for online doc ume ntation 6.3.6.3 Dist…

100%1 / 73
EDM V2.1 / Installation Manual Ausgabe 11/2012 Edition
54
at the line.
UseSmtpAuthentification Boolean
(false)
F; M; D
Enable (experimental) authentication
with username and password when
sending E-Mail notifications.
CompressionHelper.ZipCompressionLevel Integer
[0..9]
(9)
All; D
Compression rate for the EDM data
transfer. Specifies the compression
level of the algorithm used; A lower
compression rate can be required if
memory problems arise as a result of
large volumes of data during
compression.
Value range: 0 through 9.
CompatibilityMode Boolean
(false)
L; M; D
If true: Allows restricted operation of an
EDM Line Server together with an EDM
pre 2.1 Master Server. (See section
4.3)
Caution: This mode must not be used
for long-term mixed operation, but only
for step-by-step upgrading the EDM
system from pre 2.1 to 2.1. The
Modified Object protection is inactive
when the compatibility mode is active!
Note: This setting is not required when
upgrading from EDM 2.1 or higher.
Table 6-10: Settings in the SystemConig.xml file
6.3.6.1 Server type
Ke
y:
serverType
Type:
Enum
Values:
NONE
LINE
MASTER
BOTH
CLEARINGPOOL
CONFIGSERVE
R
CONFIGMASTER
CONFIGLINE
ALL
Line + Mast
er
Config S
erver + Master
Config S
erver + Line
Config Server +
Master + Line + CP + …
Valid for:
All EDM Computers running an EDM Service
Description:
Specifies the type of installation. The EDM server is started as a Line Server,
Master Server or
hybrid depending on this setting.
NOTE: The hybrid settings “BOTH” and “ALL”
should only be used for test
pur
poses!
NOTE: This value is replaced with the value from the MachineConfig.xml (see
0).
This is the fallback value for EDM
Computers that have no entry in the Machine
Configuration. The default value is “NONE”.
6.3.6.2 Help folder
Key:
helpDirectory
EDM V2.1 / Installation Manual Ausgabe 11/2012 Edition
55
Type:
Path
Default:
[AppDir]\help
Valid for:
Line server
Master server
Clearing pool
EDM Tool
Description:
Folder for online docume
ntation
6.3.6.3 Distribution list for EDM notifications
Key:
notificationDistributorClass
Type:
Class
Default:
Siemens.SiplacePro.EDM.DataExchange.EmailDistributor,
DataExchange
Valid for:
Master server
Description:
Class, i.e. implementation of the notificat
ion service. At present, distribution via
email is available using the default value as a reference.
Note:
The notificationDistributor class interface has been changed with EDM 2.1.
6.3.6.4 Configuration of EDM notification traffic
Key:
notificationDistributorConfiguratorClass
Type:
Class
Default:
Siemens.
SiplacePro.EDM.UserInterface.EmailConfigurator,
UserInterface
Valid for:
Master server
Description:
Configuration dialog box for the notification service. The actual configuration of the
notification service
depends on its implementation. Configuration of an email
service referenced using the default value is currently supported.
6.3.6.5 Notification interval
Key:
notificationInterval
Type:
Time
Default:
P0Y0M0DT0H15M0S (= 15 minutes)
Valid for:
Line server
Desc
ription:
Time period during which the change notifications will be collected on the Line
Servers before they are sent to the Master Server. The options are as follows (from
left to right
, according to the ISO 8601 standard):
Y
= years
M
= months
D
= days
H
= hours
M
= minutes
S
= seconds
The period should not be shorter than 5 minutes.
EDM V2.1 / Installation Manual Ausgabe 11/2012 Edition
56
6.3.6.6 Notification storage
Key:
notificationStorage
Type:
Endpoint
Default:
notificationStorage
Valid for:
Line server
Description:
Buffer for collected change notifications.
6.3.6.7 Master server
Key:
masterServer
Type:
String
Valid for:
Line server
Master server
Clearing pool
Description:
Network ID of the Master Server. Windows computer name only. IP addresses are
not permitted.
6.3.6.8 Transceiver
Key:
transceiverClass
Type:
Class
D
efault:
Siemens.
SiplacePro.EDM.DataExchange.MsmqTransceiver,
DataExchange
Valid for:
All EDM Applications
Description:
Implements the data transfer between the Line Servers and Master Server. This
entry must be identical on all installed systems. The exa
ct format of the "endpoint"
values depend on this value. The default setting uses MSMQ to transfer the data.
Endpoint:
An endpoint entry has the following format for the MSMQ transceiver:
Private$
\[queue-name].
Note that private queues absolutely must be
used here. Only private queues can
be used in both a domain/active directory
-based network environment as well as in
a pure workgroup installation.
6.3.6.9 Outgoing requests
Key:
masterRequests
Type:
Endpoint
Valid for:
Line server
Clearing pool
Description:
T
arget address for service requests sent by a Line Server to the Master Server.
The setting must be identical to the
Incoming Requests setting on the Master
Server.
6.3.6.10 Outgoing change notifications
Key:
masterNotifications
Type:
Endpoint