2 Functions for the Adj ustment of the Machine User’s Manual Test Program S ITEST 2.1 Axis Functions Softw are Version 403.xx Edition 12/97 2 - 6 ● Change the valu e as req uired an d confir m your e ntry by cl icking on…

100%1 / 178
User’s Manual Test Program SITEST 2 Functions for the Adjustment of the Machine
Software Version 403.xx Edition 12/97 2.1 Axis Functions
2 - 5
Click on the
Start
button in the setting box.
The selected axis will move to the target position entered. The position is displayed in the "Current
position" field (see Fig. 2.1.1).
Click on the
Update
button to update the display of the position.
If you wish to change the values for the machine parameters "Zero point cor.value", "Maximum
position" and "Minimum position", click on the
Positions...
button.
The setting box below opens.
Select the line containing the parameter you wish to edit by double-clicking.
An input box opens.
Change the value as required and confirm your entry by clicking on
Accept
.
Once you have completed all desired changes, click on the
Accept
button in the setting box.
Select the
Reference run
function to perform a reference run of the active axis.
If the selected axis is to be positioned in the continuous run mode, click on the
Continuous run...
button. The setting box below opens.
Select each line with the respective parameter you wish to edit by double-clicking.
An input box opens.
2 Functions for the Adjustment of the Machine User’s Manual Test Program SITEST
2.1 Axis Functions Software Version 403.xx Edition 12/97
2 - 6
Change the value as required and confirm your entry by clicking on
Accept
.
Once you have completed all desired entries or changes, click on the
Start
button in the setting box.
The axis moves between the start and target positions entered in the continuous run mode.
Click on the
Cancel
button in the dialog box to terminate the continuous run.
The completion time of the continuous run is displayed in the dialog box. The label of the "Cancel"
button changes to "OK".
Close the dialog box by clicking on
OK
.
If the tacho is to be adjusted to the final speed, click on the
Tacho adjustment...
button. The continu-
ous run for the adjustment of the tacho is started. The value measured for the speed deviation is dis-
played in a dialog box.
Decrease the value displayed by adjusting the tacho potentiometer on the servo board.
After the tacho has been adjusted, click on the
Cancel
button in the dialog box to terminate the contin-
uous run.
To adjust the P gain, click on the
Adust P-gain...
button.
The continuous run for the adjustment of the P gain is started. The setting box below is displayed.
By means of the and icons adjust the desired parameter group entering a value between 1
and 10.
NOTE
Depending on the parameter group entered, the positioning path will be increased or decreased.
After the adjustment of the P gain has been completed, click on the
Cancel
button in the setting box to
terminate the continuous run.
1000
Travel path
User’s Manual Test Program SITEST 2 Functions for the Adjustment of the Machine
Software Version 403.xx Edition 12/97 2.1 Axis Functions
2 - 7
2.1.2 RV Head Axis Functions
In the "RV head" display (see Fig. 0.3.5) click on the icon to switch to the "RV head, axis
functions" display.
Fig. 2.1.2 "RV head, axis functions" Display
To perform the individual functions, proceed as follows:
NOTE
Since the layout of some of the setting boxes is identical or similar to that for the gantry axis functions (see
section 2.1.1), these boxes will not be described and displayed again in this section.
In the "Axis" field activate the radio button for the axis to be adjusted ("z-axis", "dp-axis" or "Star axis").
Select the
Axis reference run
function if the axis has not been referenced yet.