00198351-01_AI_Location 2 Upgrade Kit_E by SIPLACE_en.pdf - 第20页
2 Installation of Location 2 Upgrade Kit 2.3 Recommended Installation Steps Assembly Instructions E by SIPLACE Location 2 Upgrade Kit 04/2017 20 ► Knock in the 8x28 dowel, paying attention to the recommended orientation.…

2 Installation of Location 2 Upgrade Kit
2.4 Installing the E-series Tape Cutter [03105585-xx]
Assembly Instructions E by SIPLACE
Location 2 Upgrade Kit 04/2017
26
2.4 Installing the E-series Tape Cutter [03105585-xx]
► Place the tape cutter onto the
brackets and slide it into the ma-
chine.
► Align the side holder block blind
hole with the lifting screw hole.
► Fasten the M10x100 screw (1 piece) on each side (left & right) synchronously to lift up the
tape cutter.

2 Installation of Location 2 Upgrade Kit
2.3 Recommended Installation Steps
Assembly Instructions E by SIPLACE
Location 2 Upgrade Kit 04/2017
20
► Knock in the 8x28 dowel, paying attention
to the recommended orientation.
► Tighten the M8 and two M6 screws.
► Replace the safety cover and
tighten the cover-mounting-
screws.

Assembly Instructions E by SIPLACE
Location 2 Upgrade Kit 04/2017
2 Installation of Location 2 Upgrade Kit
2.3 Recommended Installation Steps
21
► Secure the following parts together with the M4x8 countersunk screws and the M4x6 cap
screws:
– Cable, COT insert valve control [03106575-xx]
– Valve mounting plate [03109013‑xx]
– Top panel cover 4 [03106625-xx]