Product Engineering Division
SMT Section
Robotics Operations
YAMAHA MOTOR CO., LTD.
MDOC-SOFT50282
14/21
Fig 4.2 [Unit log]-[ID Log Setting]
※ When you use maintenance notice based on pickup error rate, it is recommended to
set [Server Path]. By setting [Server Path], individual log file is saved for each
Feeder ID, and information is taken over at power OFF/ON and also shared among
other machines.

Product Engineering Division
SMT Section
Robotics Operations
YAMAHA MOTOR CO., LTD.
MDOC-SOFT50282
15/21
4.2 Machine Setting
On [Machine]-[Specification Information]-[Maintenance Specification]-[Feeder], you can
change the timing to display the maintenance message.
Fig 4.3 The [Machine]-[Specification Setting]-[Maintenance Specification]-[Feeder] screen
Table 4.1 [Machine]-[Specification Information]-[Maintenance Specification]-[Feeder]
Item Function
Notice timing Timing to display the maintenance notice message or stop
error.
You can take multiple selections. For details of each item,
refer to Table 4.2.
When no item is selected, the message is not displayed.
By default, only “Feeder ON/OFF” is selected.

Product Engineering Division
SMT Section
Robotics Operations
YAMAHA MOTOR CO., LTD.
MDOC-SOFT50282
17/21
Item Function
Notice Correct X (mm)
Notice Correct Y (mm)
Stop Correct X (mm)
Stop Correct Y (mm)
▲2
For each tape type, set Feeder MACS correction value to
make maintenance notice or stop.
Only 8mm feeder and 4mm feeder are acceptable.
By switching [Feeder Group] (“SS Type” or “ZS Type”), it is
possible to set different values for SS feeder and ZS
feeder.
A recommended value is set by default (Table 4.3), so that
usually you do not need to change the value.
The allowable range is 0.000 to 999.999 (mm).
When “0.000” is set, maintenance notice and stop is
disabled for the tape.
Notice Err Rate (%)
Stop Err Rate (%)
▲2
For each tape type, set pickup error rate to make
maintenance notice or stop.
By switching [Feeder Group] (“SS Type” or “ZS Type”), it is
possible to set different values for SS feeder and ZS
feeder.
Since a recommended value is set by default (Table 4.3),
you do not need to change the value.
The allowable range is 0.00 to 10.00 (%).
When “0.00” is set, maintenance notice and stop is
disabled for the tape.
Notice Drive Cnt After
Tape Guide Maintenance
(10,000 times)
Stop Drive Cnt After Tape
Guide Maintenance
(10,000 times)
▲3
Set the number of feeding times to make maintenance
notice or stop for tape guide. This item is applied only to
auto-loading feeders.
Feeder Group:ZS Type
Tape Type:8mm
Since recommended values are set by default (Refer to
Table 4.5), you do not need to change the value.
The range is 0 to 65535 (10,000 times). If you enter “0”,
the maintenance notice or stop does not work for the tape.