Item Function
Notice Correct X (mm)
Notice Correct Y (mm)
Stop Correct X (mm)
Stop Correct Y (mm)
2
For each tape type, set Feeder MACS correction value to
make maintenance notice or stop.
Only 8mm feeder and 4mm feeder are acceptable.
By switching [Feeder Group] (“SS Type” or “ZS Type”), it is
possible to set different values for SS feeder and ZS
feeder.
A recommended value is set by default (Table 4.3), so that
usually you do not need to change the value.
The allowable range is 0.000 to 999.999 (mm).
When “0.000” is set, maintenance notice and stop is
disabled for the tape.
Notice Err Rate (%)
Stop Err Rate (%)
2
For each tape type, set pickup error rate to make
maintenance notice or stop.
By switching [Feeder Group] (“SS Type” or “ZS Type”), it is
possible to set different values for SS feeder and ZS
feeder.
Since a recommended value is set by default (Table 4.3),
you do not need to change the value.
The allowable range is 0.00 to 10.00 (%).
When “0.00” is set, maintenance notice and stop is
disabled for the tape.
Notice Drive Cnt After
Tape Guide Maintenance
(10,000 times)
Stop Drive Cnt After Tape
Guide Maintenance
(10,000 times)
3
Set the number of feeding times to make maintenance
notice or stop for tape guide. This item is applied only to
auto-loading feeders.
Feeder GroupZS Type
Tape Type8mm
Since recommended values are set by default (Refer to
Table 4.5), you do not need to change the value.
The range is 0 to 65535 (10,000 times). If you enter “0”,
the maintenance notice or stop does not work for the tape.
Product Engineering Division
SMT Section
Robotics Operations
YAMAHA MOTOR CO., LTD.
MDOC-SOFT50282
18/21
Table 4.2 Notice Timing
Notice timing Function
Power ON Displays the message when the first Return-to-Origin after
machine startup is completed.
* If feeders are on cart, the cart must be correctly set.
* When there is no correction value at the time of power-on,
Feeder MACS correction value is excluded.
Feeder ON/OFF Displays the message when attaching or removing a feeder
that requires maintenance.
* Includes the following timing.
- The cart clamp switch is turned ON/OFF by hand.
- Cart clamp ON at machine start-up.
- Cart clamp OFF at machine shutdown.
* When there is no correction value at the time of power-on,
Feeder MACS correction value is excluded.
Notice timing Function
Feeding count over Displays the message when feeding count exceeds the notice
count.
Once the message is displayed, it is not displayed again until
the board data is read or the feeder is removed (but displayed
on the other timing if selected as well).
Board change Displays the message at reading board data.
Reset Displays the message when [RESET] button is pressed.
Power OFF Displays the message when [OFF] button is pressed.
Time setting Displays the message at a given time, during auto-running or
not.
Product Engineering Division
SMT Section
Robotics Operations
YAMAHA MOTOR CO., LTD.
MDOC-SOFT50282
19/21
Table 4.3 Recommended Notice Count (Feeder maintenance period)
Notice Cnt (10,000times) Stop Cnt (10,000times)
Tape Type SS Feeder ZS Feeder SS Feeder ZS Feeder
4mm tape 5,000,000 5,000,000 7,500,000 7,500,000
8mm tape
12mm/16mm
tape
2,000,000 3,000,000
24mm tape
32mm tape 2,000,000 3,000,000
44mm tape
56mm tape
72mm tape
88mm tape
104mm tape
120mm tape
136mm tape
152mm tape
168mm tape
184mm tape